上海蔚霆生物科技有限公司作者
Human CTX-2
資料類型 | doc文件 | 資料大小 | 428544 |
下載次數 | 17 | 資料圖片 | 【點擊查看】 |
上 傳 人 | 上海蔚霆生物科技有限公司 | 需要積分 | 0 |
關 鍵 詞 | Human, CTX-2 |
- 【資料簡介】
ELISA
Human CTX-2
Catalogue Number 1A001
For the quantitative determination of Human CTX-2 concentrations in serum- body fluid - celiac fluid - tissue homogenate - culture fluid.
This package insert must be read in its entirety before using this product.
FOR RESEARCH USE ONLY.
NOT FOR USE IN DIAGNOSTIC PROCEDURES.
http://www.rapidbio.org
INTENDED USE AND TEST PRINCIPLE
This immunoassay kit allows for the quantitative determination of Human CTX-2 concentrations in serum, plasma, cell culture supernates and other biological fluids.
Add CTX-2 to pre-coated CTX-2 monoclonal antibody microelisa well, incubation; washing. Add HRP tagged CTX-2 antibodies. After another incubation and washing, remove the unbound enzyme, add Chromogen Solution A and B, the color of the liquid change into blue, and the color finally become yellow at the effect of acid. The depth of the color is positively correlated with concentration of the Porcine CTX-2 in samples.
MATERIALS REQUIRED BUT NOT SUPPLIED
1. 37 ℃ incubator
2. Standard microplate reader capable of measuring absorbance at 450 nm
3. Precision pipettes, disposable pipette tips and Absorbent paper
4. Distilled or deionized water
SAMPLE COLLECTION AND STORAGES
Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 20 minutes at approximay 1000×g. Remove serum and assay immediay or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles
Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
Note: The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.
REAGENTS PROVIDED
Reagent
Storage
MICROTITER PLATE
96 wells
2-8℃
STANDARD.I
0pg/ml 1 ml
2-8℃ (-20℃)
STANDARD.II
300pg/ml 1 ml
2-8℃ (-20℃)
STANDARD.III
600pg/ml 1 ml
2-8℃ (-20℃)
STANDARD.IV
1200pg/ml 1 ml
2-8℃ (-20℃)
STANDARD.V
2400pg/ml 1 ml
2-8℃ (-20℃)
STANDARD.VI
4800pg/ml 1 ml
2-8℃ (-20℃)
BIOLOGICAL
1.0 ml 1 vial
2-8℃ (-20℃)
ENZYME CONJUGATE
10 ml 1 vial
2-8℃
SUBSTRATE A
6.0 ml 1 vial
2-8℃
SUBSTRATE B
6.0 ml 1 vial
2-8℃
STOP SOLUTION
6.0 ml 1 vial
2-8℃
WASH SOLUTION x100
10 ml 1 vial
2-8℃
Closure plate membrane
2 strips
-
PRECAUTIONS
- Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
- Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
- Do not use kit components beyond their expiration date.
- Use only deionized or distilled water to dilute reagents.
- Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
- Use fresh disposable pipette tips for each transfer to avoid contamination.
- Do not mix acid and sodium hypochlorite solutions.
- Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Human blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
- All samples should be disposed of in a manner that will inactivate viruses.
- Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
- Substrate Solution is easily contaminated. If bluish prior to use, do not use.
- Substrate B contaFE 20% acetone, keep this reagent away from sources of heat or flame.
- Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).
ASSAY PROCEDURE
- Prepare all Standards before starting assay procedure (see Preparation Reagents). It is recommended that all Standards and Samples be added in duplicate to the Microtiter Plate.
- First, secure the desired number of coated wells in the holder, then add 50 μL of Standards or Samples to the appropriate well of the antibody pre-coated Microtiter Plate.
- Add 10 μL of Biological to samples well.(DO not add Biological to standards well).
- Add 100 μL of Enzyme Conjugate to each well. Mix well. Complete mixing in this step is important. Cover and incubate for 1 hour at 37°C.
- Prepare Substrate Solution no more than 15 minutes before end of incubation (see Preparation of Reagents).
- Wash the Microtiter Plate using one of the specified methods indicated below:
- Manual Washing: Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with distilled or de-ionized water, then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure four more times for a total of FIVE washes. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly hen washing the plate to assure that all strips remain securely in frame.
- Automated Washing: Aspirate all wells, then wash plate FIVE times using distilled or de-ionized water. Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350 μL/well/wash (range: 350-400 μL). After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. It is recommended that the washer be set for a soaking time of 10 seconds or shaking time of 5 seconds between washes.
- Add 50 μL Substrate A&B to each well. Cover and incubate for 15 minutes at 20-25°C.
- Add 50 μL of Stop Solution to each well. Mix well.
- Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 30 minutes.
CALCULATION OF RESULTS
- This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.
- First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.
- To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
- Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
- The sensitivity by this assay is 10 pg/ml.
- Standard curve
上海逸晗生物科技有限公司代理不同品牌價格檔次的ELISA試劑盒??贵w產品等, 品種多,質量好,價格實惠,并且還提供免費代檢測服務。
本公司的更多產品,請點擊公司:http://www.yihanbio.com/
上一篇:德國IONTIS靜電消除器
下一篇:荷蘭Bronkhorst流量計
- 凡本網注明"來源:環保在線"的所有作品,版權均屬于環保在線,轉載請必須注明環保在線,http://www.kindlingtouch.com。違反者本網將追究相關法律責任。
- 企業發布的公司新聞、技術文章、資料下載等內容,如涉及侵權、違規遭投訴的,一律由發布企業自行承擔責任,本網有權刪除內容并追溯責任。
- 本網轉載并注明自其它來源的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點或證實其內容的真實性,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品來源,并自負版權等法律責任。
- 如涉及作品內容、版權等問題,請在作品發表之日起一周內與本網聯系,否則視為放棄相關權利。