NRP/NRP2功率計在電子測試與測量領域中,精確測量射頻功率是挑戰性的任務之一
NRP/NRP2功率計在電子測試與測量領域中,精確測量射頻功率是挑戰性的任務之一。無論是在測量移動通信中的某個射頻模塊,或是在復雜雷達系統、基站或的應用中,都是需要盡可能精確的功率測量。這種要求不僅體現在實驗室校準應用上,同時也體現在研發,生產,維修等應用中。
NRP-Z系列射頻功率探頭無論在實驗室還是在生產線,微波功率計R&S NRP都是你正確的選擇。新穎的R&S NRP系列功率計的通用性主要歸因于新近開發的功率探頭。這些探頭是智能的獨立儀器,他們與基本單元通訊,或經由數字接口與一個pc機通信。現在實現的智能傳感技術,建立了根據通用性和準確性要求的新標準。
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 8 GHz,
N connector
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -57 dBm to +33 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -47 dBm to +42 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -42 dBm to +45 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 33 GHz,
3.5 mm connector
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 8 GHz,
N connector
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -30 dBm to +20 dBm,
Frequency range: DC to 18 GHz,
N connector
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 33 GHz,
3.5 mm connector
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 40 GHz,
2.92 mm connector
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 44 GHz,
2.92 mm connector
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 50 GHz,
2.4 mm connector
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 67 GHz,
1.85 mm connector
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 110 GHz,
1.00 mm connector
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 18 GHz,
N connector
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.92 mm connector
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.4 mm connector
Accurate average power measurements for EMC applications
Measurement range: -67 dBm to +23 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
Accurate average power measurements for EMC applications
Measurement range: -57 dBm to +33 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
Highly accurate signal level generation in conjunction with a signal generator
Measurement range: -67 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
Highly accurate signal level generation in conjunction with a signal generator
Measurement range: -67 dBm to +20 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 18 GHz,
N connector
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 26.5 GHz,
3.5 mm connector
Convenient power measurements via PC application
In some cases the signal source is far away from the base unit. Therefore four different sensor extension cables are available, to get a total length of 3, 5 or 10 meters.
R&S®NRP-Z3 active USB adapter has been developed for applications requiring external triggering of the power sensor. It also offers a separate power supply.
For all R&S®NRP-Z sensors. The R&S®NRP-Z4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lenghths: 2.0m, 0.5m, 0.15m and 1m (for panel-mount)
R&S®NRP-Z5 can host up to 4 R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.