Thermal conductivity tester is a testing instrument for measuring the thermal conductivity of various homogeneous plate-like thermal insulation materials and the determination of composite plates. Be sure to read the instructions carefully before use. It is operated by experimental personnel to avoid injury caused by improper operation. For more information, please contact our customer service staff.
The thermal conductivity tester is designed and manufactured in accordance with GB / 10294-2008 "Determination of steady-state thermal resistance and related characteristics of thermal insulation materials, heat flow meter method". Applicable to testing units, colleges and universities, research and production units. The large-screen touch screen has the advantages of easy operation and high intelligence.
導熱系數測定儀主要特點:
★微機自動控制,自動完成數據采集和生成報表,智能化程度高,使檢測快捷、準確。
★主機箱采用復合沒計,使用方便,外觀新穎大方。
★冷單元部分采用自動汽缸夾緊,氣動系統壓力值可調。
★冷系統采用全封閉式壓縮機組,冷卻快、制冷均勻、運行噪音小。
★計量加熱單元采用紫銅板作為加熱面板。具有高導熱性,使溫度均勻熱慣性小,測量結果更準確。
Main characteristics of thermal conductivity tester:
★ Microcomputer automatic control, complete data collection and report generation automatically, high degree of intelligence, make detection fast and accurate.
★ The main box adopts composite design, convenient to use and novel in appearance.
★ The cold unit is clamped by an automatic cylinder, and the pressure value of the pneumatic system is adjustable.
★ The cooling system uses a fully enclosed compressor unit, which has fast cooling, uniform cooling and low operating noise.
★ The metering heating unit uses a copper plate as the heating panel. With high thermal conductivity, uniform temperature and low thermal inertia, more accurate measurement results.
導熱系數測定儀技術參數:
★熱板溫度范圍:常溫—80℃
★冷板溫度范圍:10~50℃
★試件規格尺寸:300X 300mm
★試件厚度范圍:10~40mm
★測試準確度:≤±3%
★電源、功率:220V/2KW
★外形尺寸:800×600×1600mm
Technical parameters of thermal conductivity tester:
★ Temperature range of hot plate: normal temperature—80 ℃
Type thermal conductivity tester, using double test piece measuring device, protective hot plate group: including heating unit, cooling unit. The heating unit shall be divided into a metering unit in between and a protective unit surrounding the metering unit separated by a gap, and equipped with thermal insulation. The hot unit adopts double hot surface heaters. The cold plates are arranged symmetrically with the double hot surfaces. The thickness of the test piece sets the space for moving the cold plate. The test piece is placed vertically in two flat plates with constant temperature parallel to each other. In the steady state, the measurement part of the test piece has a constant heat flow. By measuring the one-dimensional constant heat flow Q flowing through the metering unit, the area A of the metering unit, and the temperature difference T between the cold and hot surfaces of the test piece, it can be calculated. According to the thickness of the test piece, the thermal resistance R of the test piece can be accurately calculated.
The grounding protection wire must be reliably grounded. Check whether the power supply voltage is normal before starting up.
Refrigeration system is strictly forbidden to start continuously. The start interval should be more than 3 minutes.
The test temperature of the test piece must be lower than the melting point of the test piece.
The temperature is too high, the power is cut off, and the cause can be checked again.
After the test, click the "Auto Detect" button to reset and then click the "Exit" button.
Do not click "Exit" and "Manual Control" during automatic operation, otherwise the experiment will be terminated or out of control.
Refrigeration system refrigerant isR十二.
Do not touch any live parts while the system is powered on.
When the device is transported and moved, it is forbidden to pry the bottom with a pole to avoid damaging the refrigeration system. Use the top ring to move or carry during transportation. The tilt angle of the whole machine should not exceed 45 ° during transportation to prevent damage to the refrigeration compressor.