EITPALMProbeFeatures?WideDynamicRange(100,000:1)Measurements

詳細介紹

EIT PALM Probe


Features

 

Wide Dynamic Range (100,000:1) Measurements; Autoranging and zeroing

Measures and displays Watts, Joules, Seconds; displays peak value Watts/cm2

 

Electrically isolated and insulated Light Guide

Very high temperature resistant Light Guide

Single hand operation; two membrane switch control

UV bands- choice of EIT UVA, UVB, or UVV

Battery powered; two user replaceable AA batteries with low battery warning

 

Applications

 

Measure UV system performance particularly in applications where measurement space is limited or it is difficult to access

Establish, document and maintain UV process windows

 

Meet  ISO,  quality  and  customer  requirements  for

SPC/SQC

 

Verify readings from on-line sensors; coordinate relative percentage type readings from on-line displays to absolute units

 

Multiple uses from production curing (high irradiance) to stray hazard (low irradiance) applications

 

Introduction

 

The PALM Probe radiometer from EIT addresses UV Measurement and Process Control in areas where it has been difficult to pass a radiometer through the process. The use of UV inks and coatings has grown in label and web markets and the PALM Probe offers safe, reliable measurement for these and other applications.

 

The word PALM is an acronym for Production Ambient Light Measurement. The PALM Probe has an extremely wide dynamic range allowing it to read from very low levels of UV light as in fluorescent bulbs to very high levels of UV found in powerful UV curing systems. The physical conditions inside a UV curing chamber are harsh. An instrument must withstand wide temperature variations. A tremendous amount of electrical energy is used to excite the UV bulb. The PALM Probe is designed to withstand the harsh physical conditions of the UV curing chamber as well as protect the operator and instrument from damage or electrical shock. Potentially lethal voltages exist in UV curing systems. Although the Light Guide has been designed to reduce the risk of shock, the user should avoid contact with the high voltage areas in the UV housing. The user holds the Probe Body of the instrument and inserts the Light Guide under the UV source.

 

Operation

 

Ultraviolet, visible and infrared light radiation of all wavelengths impinge on the Input Aperture at the tip of the PALM Probe Light Guide. The light is directed down the

Light Guide to the base of the Probe body where the UV filter passes the UV light of interest to the photodetector. The photodetector converts the light energy to a current that is proportional to its intensity. The signal is conditioned, digitized, processed and displayed on the LCD of the PALM Probe.

 

 

The Light Guide is constructed out of steel alloy and coated with a non-conductive ceramic coating to insulate and protect the user from accidental shock while taking measurements. The Light Guide is further isolated from the Probe Body by a non-conductive Delrin block. The Probe Body contains the optics, electronics, battery and display functions of the unit. The Probe Body can be held either with an ‘over’ or ‘under’ hand type of grip. The raised membrane switches are easy to operate with either hand.

 

The PALM Probe has a very wide dynamic range that automatically adjusts itself for the user. For example, the PALM Probe can measure light from approximately 100 microWatts/cm2 (µW/cm2) up to 10 Watts/cm2 (W/cm2). The decimal point in the LCD ‘floats’ over three places to cover the wide dynamic range on the unit

 

The PALM Probe display allows the user to alternate between Watts-Joules-Seconds during data collection and after a reading or run has been made. The SELECT button allows the user to toggle between the values.

 

When collecting irradiance data with the PALM Probe, the display will change as the Probe changes position under the UV source. As the aperture opening moves into the focused peak irradiance area of the UV source, the reading will increase. Variations in irradiance may also be seen when the PALM Probe is moved along the length of a UV bulb. The LCD display will automatically scale and adjust as the PALM

Probe takes readings. Pressing the RUN/STOP button will stop the collection of data and the highest irradiance value measured during the collection of data will be displayed. Most users will find that the Irradiance value (W/cm2) displayed is the most important value collected by the PALM Probe when it comes to process control for a particular application.

 

UV Energy Density or Dose incorporates time into the irradiance measurement. The PALM Probe displays the Energy Density or Dose value in Joules (J/cm2 ) on the LCD.

 

The dose is an integration of the area under the irradiance curve. The dose reading increases as the reading continues. The speed at which the dose increases depends on the irradiance value. Switching to the built in timer in the PALM Probe will help monitor the ‘time component’ of the dose reading for more consistent results. Placement of the PALM Probe in the same location is important in order to get consistent and repeatable irradiance values to calculate dose readings.

 

LCD Display

 

The following diagram shows all the available LCD Displays on the PALM Probe. In operation, the display is easy to read and understand as the user will only see the segments on the display that pertain to current rea

 

system and allows the Light Guide to be inserted in the same location each time. The Locator Kit has been designed to mount in either direction (shown below). It is available without the hinged door.

 

 EIT On-line Monitoring EquipmentThe readings from the PALM Probecan be coordinated with the readings obtained from EIT On-line monitoring instruments. When conditions are ideal (clean reflector, new UV lamps), the EIT 

displays can be set to read 99% UV intensity. Baseline readings of the UV intensity can be obtained with the PALM Probe. The UV will generally decrease over time as the reflectors and UV bulbs change. The readings displayed on the EIT on-line monitors can be compared to the readings on the PALM Probe. The On-line monitors can provide continuous monitoring including alarm

 

functions and feedback information. The PALM Probe also allows users to compare readings between systems.

Specifications


 reading Watts,Joules orSeconds



4 digit display with


Hand Unit Temperature-displayed

floating decimal pt.


when entering run mode




PALM Probe Placement

 

Placement of the PALM Probe needs to be in a regular and repeatable location to achieve consistent results. EIT has developed two accessories to help with this.

 

The first accessory is supplied with each unit and attaches over the light guide to allow it to be positioned to the same ‘stop’ depth each time the PALM Probe is used to take a reading.

The second accessory to help with placement of the PALM Probe is a Locator Kit. The Locator Kit is mounted on the



其他推薦產品更多>>

感興趣的產品PRODUCTS YOU ARE INTERESTED IN

環保在線 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.kindlingtouch.com,All rights reserved.

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,環保在線對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
主站蜘蛛池模板: 颍上县| 思南县| 偃师市| 佛坪县| 连州市| 新和县| 兴国县| 吕梁市| 花垣县| 宜章县| 仪征市| 潼关县| 宣化县| 华亭县| 盘锦市| 福清市| 固阳县| 若尔盖县| 松潘县| 娱乐| 江川县| 岳池县| 大城县| 微山县| 洪湖市| 汉中市| 三都| 文化| 徐闻县| 阿拉善左旗| 吴川市| 台东县| 藁城市| 渝北区| 马龙县| 迁安市| 杭锦后旗| 斗六市| 肇源县| 金塔县| 梁平县|