Epoxy resin dielectric constant tester meet standard: GBT 1409-2006 to measure the electrical insulation in power frequency, audio frequency, high frequency (including m wavelength) the recommended method of the dielectric constant and dielectric loss factor
Dielectric loss and dielectric constant are various electrical porcelain, porcelain, capacitor, such as ceramic, and composite materials such as one of the important physical properties, by measuring dielectric loss Angle tangent tan delta and dielectric constant (epsilon), to further understand the various factors influencing the dielectric loss and dielectric constant, and provide the basis for improve the performance of materials;
The basic principle of the instrument is to adopt the high frequency resonance method and provide the general, multi-purpose, multi-range impedance test.
Epoxy resin dielectric constant test instrument with single chip computer as control instrument, frequency measuring core with the digital lock, standard frequency test point set automatically, automatic resonance point search, Q value range automatic conversion, numerical display new technology, such as improved tuning loop, the tuning test circuit minimizes the residual inductance, and keep the original Q table automatic painting techniques, makes the new instrument when use more convenient, more accurate measurements.
Instrument can under the condition of high test frequency, measuring the high frequency inductive or Q value of resonance loop, inductance and distributed capacitance of inductance and capacitance of capacitor and loss tangent value, electrical material of dielectric loss at high frequency, high frequency circuit effectively in parallel and series resistance, the characteristic impedance of a transmission line, etc.
Technical index of epoxy resin dielectric constant tester
1. Q value measurement
A. Q range: 2 ~ 1023.
B. Q value range: 30, 100, 300, 1000, automatic shift or manual shift.
C. Nominal error
project GDAT - A
Frequency range 10 KHZ ~ 10 MHZ;
Inherent error 2% of 5% plus or minus full value;
Operating errors 2% of the value of 7% plus or minus;
Frequency range 10 MHZ to 160 MHZ;
Inherent error 2% of the value of 6% plus or minus.
Operating errors 2 percent of the value of 8% plus or minus.
Electrode separation adjustment
The measurement of the cylinder electrode and the flat electrode can not be measured with one electrode.
Characteristics of epoxy resin dielectric constant tester:
The range is high, the accuracy is good!
No conversion
Color touch screen system can be set without switching