Svantek SVAN 979 Sound Level Meter & Vibration Analyzer

詳細介紹

  詳情:

  • Class 1 IEC 61672:2013 sound level measurements

  • General vibration measurements (acceleration, velocity and displacement)

  • Three parallel independent profiles

  • 1/1, 1/3 octave real-time analysis

  • 1/6 or 1/12 octave real-time analysis (option)

  • FFT real-time analysis 1600 lines in up to 22.4 kHz band

  • Time-domain signal recording

  • Advanced data logger including spectra’s logging and Audio Events Recording

  • Reverberation Time measurements (RT60)

  • Pure tone detection (option)

  • Acoustic loudness measurements (option)

  • Advanced trigger and alarm functions

  • User programmable Band-Pass Filters

  • Windscreen and extension cable auto detection

  • Built-in self vibration measurements

  • MicroSD card for mass data memory

  • Remote communication by GPRS or LAN & WLAN (optional hardware required)

  • GPS time synchronisation (optional hardware required)

  • USB 1.1 Client interface (real-time PC “front end")

  • Bluetooth®, RS 232 and IrDA interfaces

  • Super contrast (10000:1) colour OLED display

  • Built-in signal generator

  • All weather microphone protection SA 279

  • Hand held, light weight and robust case

  • Easy in use

 

The SVAN 979 Class 1 Sound & Vibration Analyzer is our flagship device. Your first impression will be the amazing OLED display which features excellent visibility in all light conditions. The instrument’s lightweight and durable aluminium housing not only gives a sense of a firm grip but also protects the valuable electronic device from damage and any influence from electromagnetic interference.

The SVAN 979 has a very large dynamic range of measurement - over 110dB. It’s high-quality GRAS 40AE microphone allows measurement in the frequency range starting as low as 3 Hz. The measurement path has been designed to allow the use of other microphones should you want to measure very low frequencies or very high levels of noise. The microphone preamplifier has also been reinforced with a collar to protect against mechanical damage. One amazing feature of the SVAN 979 is that if you disconnect the microphone preamplifier then you can use the instrument for vibration measurements - simply connect up a cable and a vibration sensor .

The SVAN 979 has an extensive range of hardware and firmware add-ons that includes built-in Bluetooth®, windscreen infrared detector, direct connections to GPS module, GPRS or Wireless LAN modem or the totally unique built-in vibration shock sensor that warns the user whenever the instrument itself is exposed to vibrations that may influence the noise measurements. 

Two USB connectors allow for the simultaneous operation of USB pen-drives and communication with the computer. Usage of this number of advanced features at the same time is possible as the instrument has two high-speed digital signal processors. For example, the SVAN 979 is capable of measuring 2 ms steps of time history, logged simultaneously to audio recording (with 48kHz sampling) and real-time frequency analysis. Only the SVAN 979 can meet such a challenge. All data is stored on a microSD card of any capacity (default is 8GB).

It is also important to note that unlike other brands which recalculate FFT spectrum to octave bands, the SVAN 979 performs frequency analysis in real-time, whether in octaves, third octaves all the way up to 1/12 octaves. Setting up such advanced measurements can be very complicated but not in the SVAN 979. The intuitive menu structure of this instrument has been designed to make the measurement experience a pleasure.

StandardsClass 1: IEC 61672-1:2013 (PTB approval 21.21/13.06)
Number of Profiles3
Weighting FiltersA, B, C, Z, G
Time constantsSlow, Fast, Impulse
RMS DetectorDigital True RMS detector with Peak detection, resolution 0.1 dB 
MicrophoneGRAS 40AE, 50 mV/Pa, prepolarised 1/2" condenser microphone
PreamplifierSV 17 IEPE type / 200V external polaristation compatible
Linear Operating Range22 dBA RMS ÷ 140 dBA Peak (in accordance to IEC 61672)
Total Dynamic Measurement Range12 dBA RMS ÷ 140 dBA Peak (typical from noise floor to the maximum level)
Internal Noise Level less than 12 dBA RMS
Dynamic Range>110 dB
Frequency Range

3.15 Hz ÷ 20 kHz with GRAS 40AE microphone

Meter Mode ResultsSPL, Leq, SEL, Lden, LEPd, Overload time, Ltm3, Ltm5, LMax, LMin, LPeak,
Simultaneous measurement in three profiles with independent filters and detectors
Statistics

Ln (L1-L99), complete histogram in meter mode, averaging: linear of with detector (exponential)

Ln (L1-L99) statistics in 1/1 or 1/3 octaves (if option is active)

Data Logger

logging of summary results with step from 10 s (auto-save function)

logging of time history with step from 2 ms

Audio Recording (option)Audio events recording during measurement, trigger or continuous mode, 12 / 24 / 48 kHz sampling rate, 16 or 24 bit, wav format
Wave Recording (option)Time domain signal recording during measurement 12 / 24 / 48 kHz sampling rate, 16 or 24 bit, wav format

Sound Analyser

1/1 Octave Analysis (included)

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 31.5 Hz to 16 kHz (audio band), selectable weighting filter, selectable detector or

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 1 Hz to 16 kHz  (full band), selectable weighting filter, detector linear

1/3 Octave Analysis (inlcuded)

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 20 Hz to 20 kHz (audio band), selectable weighting filter and selectable detector or

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.8 Hz to 20 kHz  (full band), selectable weighting filter, linear detector

1/6 Octave Analysis (option)

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 20 Hz to 21.4 kHz (audio band), selectable weighting filter and selectable detector or

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.73 Hz to 21.4 kHz  (full band), selectable weighting filter, linear detector

1/12 Octave Analysis (option)

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 20.3 Hz to 22 kHz (audio band), selectable weighting filter and selectable detector or

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.71 Hz to 22 kHz  (full band), selectable weighting filter, linear detector

 FFT Analysis (included)

400 or 800 or 1600 lines in selectable band from 78 Hz to 20 kHz with selectable weighting filter, selectable averaging: linear or exponential, and selectable window

Tonality (option)Pure tone detection, FFT -based,  according to Joint Nordic Method and ISO 1996
RT 60 (included)

Reverberation time analysis in 1/3 octaves, selectable method: decay or impulse

Signal Generator (included)Sine, White noise, Pink noise
RPM (option)Rotation measurement option without Laser Tachometer (option), measurement of RPM, RPS, RMAX, RMIN
User filters (option)Selectable real time filter: low pass, high pass and band pass filters option

Vibration Level Meter

StandardsISO 10816-1
Number of Profiles3
Weighting Filters

Acceleration: HP1, HP3, HP10, Wh; Velocity: Vel1, Vel3, Vel10, Displacement: Dil1, Dil3, Dil10

Machine filter: VelMF (ISO 10816-1)

RMS DetectorDigital True RMS detector with Peak detection, resolution 0.1 dB
Time constants: from 100 ms to 10 s
Meter mode resultsRMS, MAX, Peak, Peak-Peak, Overload time, MTVV,
Accelerometer (option)SV 80 IEPE, single axis, sensitivity 10 mV/(ms-2) ~ 100 mV/g
Measurement Range0.01 ms-2 RMS ÷ 500 ms-2 Peak (with SV 80)
Frequency Range1 Hz ÷ 5 kHz (with SV 80 and HP or HP1 filter)

Vibration Analyser

1/1 Octave Analysis (included)

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 1 Hz to 16 kHz  (full band), HP weighting filter, detector linear

1/3 Octave Analysis (inlcuded)

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.8 Hz to 20 kHz  (full band), HP weighting filter, detector linear

1/6 Octave Analysis (option)

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.73 Hz to 21.4 kHz  (full band), HP weighting filter, detector linear

1/12 Octave Analysis (option)

Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.71 Hz to 22 kHz  (full band), HP weighting filter, detector linear

 FFT Analysis (included)

400 or 800 or 1600 lines in selectable band from 78 Hz to 20 kHz with selectable weighting filter, selectable averaging: linear or exponential, and selectable window

RPM (option)Rotation measurement option without Laser Tachometer (option), measurement of RPM, RPS, RMAX, RMIN
User filters (option)Selectable real time filter: low pass, high pass and band pass filters option

General information

InputLEMO 7-pin: Direct AC, Direct AC with 200 V polarisation, Direct DC or IEPE type with TEDS
Self-vibration MonitoringBuilt-in shock detection
Dynamic Range115 dB
Frequency Range

0.5 Hz ÷ 22.4 kHz, sampling rate 48 kHz

0.5 Hz ÷ 40 kHz, sampling rate 96 kHz (ultrasound version)

Memory32 MB non-volatile flash type, micro SD card 8 GB (removable & upgradeable)
DisplayColour 320 x 240 pixels, OLED type
Keyboard9 push buttons
Communication InterfacesUSB 1.1 client
Bluetooth®
RS 232 (with SV 55 option)
GPS time synchronisation and positioning (option)
External I/O - AC output (1 V Peak) or Digital Input/Output (Trigger – Pulse)
 Power supplyFour AA rechargeable NiMH batteries (included)
USB interface 500 mA HUB
External power supply 6 V/500 mA DC ÷ 15 V/250 mA DC
SA 17A external battery pack (option)
Environmental ConditionsTemperature from -10 oC to 50 oC
Humidity up to 90% RH, non-condensed
Dimensions305 mm x 79 x 39 mm (including microphone and preamplifier)
Weight Approx. 0.6 kg with batteries

 


感興趣的產品PRODUCTS YOU ARE INTERESTED IN

環保在線 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.kindlingtouch.com,All rights reserved.

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,環保在線對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
主站蜘蛛池模板: 曲阳县| 濮阳县| 栾城县| 福安市| 吴忠市| 临猗县| 大关县| 于田县| 隆德县| 依兰县| 靖西县| 永兴县| 沈丘县| 共和县| 永新县| 冷水江市| 彭州市| 德惠市| 军事| 安塞县| 遵义县| 宜宾县| 黎川县| 杂多县| 加查县| 乌鲁木齐县| 武胜县| 张家界市| 靖远县| 唐山市| 琼中| 库尔勒市| 开封市| 吴旗县| 县级市| 田阳县| 花莲县| 响水县| 冷水江市| 大城县| 曲靖市|