CHB200W SERIES
132 - 200 WATT 4:1 INPUT DC-DC CONVERTERS
FEATURES
- 132-200W Isolated Output
- Half Brick Package
- 4:1 Input Range
- Regulated Output
- Efficiency to 89%
- Input Under Voltage Protection
- Over Temperature Protection
- Over Voltage/Current Protection
- Remote On/Off Control
- 1500VDC Isolation
- Continuous Short Circuit Protection
- CE Mark Meets 2004/108/EC
- UL60950-1 Approval (Except 28 Vout)
MODEL | INPUT | OUTPUT | OUTPUT CURRENT | INPUT CURRENT |
| CAPACITOR | ||
|
|
|
| % EFF. | ||||
NUMBER | VOLTAGE | VOLTAGE | MIN. | MAX. | NO LOAD | FULL LOAD |
| LOAD MAX. |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
CHB200W-24S3V3 | 10-36 VDC | 3.3VDC | 0 mA | 50 A | 130 mA | 7.90 A | 87 | 10000µF |
CHB200W-24S05 | 10-36 VDC | 5.0VDC | 0 mA | 40 A | 150 mA | 9.58 A | 87 | 10000µF |
CHB200W-24S12 | 10-36 VDC | 12 VDC | 0 mA | 16.7 A | 50 mA | 9.71 A | 86 | 2200µF |
|
|
|
|
|
|
|
|
|
CHB200W-24S15 | 10-36 VDC | 15 VDC | 0 mA | 13.3 A | 50 mA | 9.56 A | 87 | 2200µF |
CHB200W-24S24 | 10-36 VDC | 24 VDC | 0 mA | 8.3 A | 45 mA | 9.54 A | 87 | 2200µF |
|
|
|
|
|
|
|
|
|
CHB200W-24S28 | 10-36 VDC | 28 VDC | 0 mA | 7.14 A | 55 mA | 9.41 A | 88.5 | 2200µF (2) |
CHB200W-24S48 | 10-36 VDC | 48 VDC | 0 mA | 4.2 A | 60 mA | 9.77 A | 86 | 2200µF (3) |
CHB200W-48S3V3 | 18-75 VDC | 3.3VDC | 0 mA | 40 A | 80 mA | 3.13 A | 88 | 10000µF |
CHB200W-48S05 | 18-75 VDC | 5.0VDC | 0 mA | 40 A | 80 mA | 4.68 A | 89 | 10000µF |
CHB200W-48S12 | 18-75 VDC | 12 VDC | 0 mA | 16.7 A | 60 mA | 4.74 A | 88 | 2200µF |
|
|
|
|
|
|
|
|
|
CHB200W-48S15 | 18-75 VDC | 15 VDC | 0 mA | 13.3 A | 60 mA | 4.72 A | 88 | 2200µF |
CHB200W-48S24 | 18-75 VDC | 24 VDC | 0 mA | 8.3 A | 60 mA | 4.72 A | 88 | 2200µF |
|
|
|
|
|
|
|
|
|
CHB200W-48S28 | 18-75 VDC | 28 VDC | 0 mA | 7.14 A | 50 mA | 4.68 A | 89 | 2200µF (2) |
CHB200W-48S48 | 18-75 VDC | 48 VDC | 0 mA | 4.2 A | 50 mA | 4.83 A | 87 | 2200µF (3) |
NOTE: |
|
|
|
|
|
|
|
|
- Nominal Input Voltage 24, 48 VDC
- The Output Terminal of 28Vout Models Required a Minimum Capacitor 100uF to Maintain Specified Regulation.
- The Output Terminal of 48Vout Models Required a Minimum Capacitor 47uF to Maintain Specified Regulation.
- 西安云特電子技術有限公司
- 盧旭斌
- /13
- www.yuutee。。cn