This indicator can be connected with strain gauge type load cell and pressure transducer to show data detected by those transducers. It has various functions to process data, form judgement, and output to outer appliances.
FEATURES
Functional Digital Calibration Instead of actual load calibration, this indicator adopts digital calibration by inputting rated voltage output (mV/V).
Easy to Check Graphic LCD Easily make settings on the indicator in dialog style by checking messages on the graphic LCD.
Various Digital Processing Analog signals from transducers will be effectively converted into digital signals by A/D converter at the rate of 640 times/sec.
Inligent Judgement Function By lighting on the HI, OK, or LOW lamp and proceeding signal output to judge the test result.
DIGITAL INDICATOR
MODEL:IND-7660
Enjoying Plenty of Functions for Automatic Control
This indicator can be connected with strain gauge type load cell and pressure transducer to show data detected by those transducers. It has various functions to process data, form judgment, and output to outer appliances.
Features
lFunctional Digital Calibration
Instead of actual load calibration, this indicator adopts digital calibration by inputting rated voltage output (mV/V).
lEasy to Check Graphic LCD
Easily make settings on the indicator in dialog style by checking messages on the graphic LCD.
lVarious Digital Processing
Analog signals from transducers will be effectively converted into digital signals by A/D converter at the rate of 640 times/sec.
lInligent Judgement Function
By lighting on the HI, OK, or LOW lamp and proceeding signal output to judge the test result.
lOptions
Models with RS-232C interface or analog output (4-20mA) are available.
Specifications
Range of Gain Adjustment
Full scale setting of 0.5mV/V~2.5mV/V
Value Display Range
±10000
Linearity
0.05% of F.S.±1digit
A/D Converter
16 bit 640 times/sec.
LED Lamp
4 lamps Red (HI, LOW) Green (OK) Yellow (HOLD)
Key Switch
4 switches ZERO, MENU, RESET, HOLD
Comparator Function
Top/bottom value setting
Data Hold Function
Peak, bottom, signal from outer appliances, peak or bottom data in limited area, limited period top point or change point
Output Signal
Open collector O.L, HI, OK, LOW
Input Signal
Contact point or open collector ZERO, HOLD, RESET
Outer Power Supply
DC24V for input/output signal isolation
Optional Models
Indicator unit with RS-232C interface
Indicator unit with analog output 4-20mA
Power Supply
AC 85V~265V
Operation Condition
Temperature:5`40℃
Humidity less than 85%RH (No bedewing)
Outer Dimension
96W x 96H x 155D mm (Panel cut 92x92mm)
Weight
Approx. 900g
※The above specifications are subject to change without notice