丹富斯200X減壓閥是一種利用介質自身能量調節與控制管路壓力的職能型閥門。 200X減壓閥用于生活給水、消防 給水及其他工業給水系統,通過調節減壓導閥,即可調節主閥的出口壓力。出口壓力不因進口壓力、進口流量的 變化而變化,安全可靠地將出口壓力維持在設定值上,并可根據需要調節設定值以達到減壓目的。該閥減壓精確, 性能穩定、安全可靠、安裝方便,使用壽命長。 丹富斯減壓閥、可調式減壓閥、減壓閥規格。
Dan fuss, 200 x pressure reducing valve is a kind of USES the energy of medium type and the function of control line pressure valve adjustment. 200 x pressure reducing valve used in the drinking water, fire water, and other industrial water supply system, by adjusting the pressure pilot valve, can adjust the outlet pressure of the main valve. Outlet pressure does not change due to the change of inlet pressure, inlet flow, safe and reliable to keep outlet pressure on the set value, and can according to need to adjust the Settings to achieve the relief. The valve decompression precision, stable performance, safe and reliable, easy installation, long service life.
丹富斯200X減壓閥結構特點和用途: 丹富斯減壓閥、可調式減壓閥、減壓閥規格。
200X減壓閥由主閥、導閥、針閥、球閥、微型過濾器和壓力表組成水力控制接管系統。使用時,當調定出口壓力后,能自動保持穩定出口壓力。本產品利用導閥自力控制,不需要其它裝置和能源,保養簡便,壓力控制準確度高,受進口壓力和流量影響小,減壓穩壓可靠。200X減壓閥廣泛用于高層建筑、生活區等供水管網系統及城市供水工程。
Dan fuss, 200 x pressure reducing valve structure features and use:
200 x pressure reducing valve consists of the main valve and pilot valve, needle valve, ball valve, micro filter and pressure gauge of hydraulic control of system. After use, when the setting outlet pressure, stable outlet pressure automatically. This product use pilot valve to control themselves, do not need other devices and energy sources, convenient maintenance, pressure control accuracy is high, affected by the inlet pressure and flow rate is small, reduced pressure regulator is reliable. 200 x pressure reducing valve is widely used in water supply network system of high-rise buildings, residential and urban water supply engineering.
丹富斯200X減壓閥工作原理:
當閥門從進口端給水時,水流過針閥進入主閥控制室,出口壓力通過導管作用到導閥上。當出口壓力高于導閥彈簧設定值時,導閥關閉。控制室停止排水,此時主閥控制室內壓力升高并關閉主閥,出口壓力不再升高。當閥門出口壓力降到導閥彈簧設定壓力時,導閥開啟,控制室向下游排水。由于導閥系統排水量大于針閥的進水量,主閥控制室壓力下降。進口壓力使主閥開啟。在穩定狀態下,控制室進水、排水相同,主閥開度不變,出口壓力穩定。
Dan fuss, 200 x pressure reducing valve working principle:
When the valve from the inlet water supply, water flows through a needle into the main valve control room, outlet pressure through the catheter to the pilot valve. When the outlet pressure is higher than the pilot valve spring set value, pilot valve to close. Control room to stop drainage, at this time the main valve to control the indoor pressure and close the main valve, outlet pressure is no longer increases. When the valve outlet pressure down to guide valve spring set pressure, the pilot valve open, the control room to the downstream drainage. Because the pilot valve system of displacement is greater than the needle valve into the water, the main valve control room pressure drop. Open the main valve inlet pressure. Under steady state, the control room the same feed water and drainage, the main valve opening is changeless, outlet pressure stability.
丹富斯200X減壓閥主要技術參數:
Dan rich, 200 x pressure reducing valve, main technical parameters: