日韩午夜在线观看,色偷偷伊人,免费一级毛片不卡不收费,日韩午夜在线视频不卡片

行業產品

  • 行業產品

廈門慧嘉生物科技有限公司


當前位置:廈門慧嘉生物科技有限公司>技術文章>(ADMA)大鼠不對稱二甲基*(ADMA)ELISA Kit
技術文章

(ADMA)大鼠不對稱二甲基*(ADMA)ELISA Kit

閱讀:228發布時間:2012-8-12

 1

Rat Asymmetrical
Dimethylarginine(ADMA)
ELISA Kit
(96T)
This immunoassay kit allows for the in vitro quantitative determination of rat
ADMA concentrations in serum, plasma.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
2
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with
a goat-anti-rabbit antibody. Standards or samples are then added
to the appropriate microtiter plate wells with a HRP-conjugated
ADMA and antibody preparation specific for ADMA and
incubated. Then substrate solutions are added to each well. The
enzyme-substrate reaction is terminated by the addition of a
sulphuric acid solution and the color change is measured
spectrophotometrically at a wavelength of 450 nm ± 2 nm. The
concentration of ADMA in the samples is then determined by
comparing the O.D. of the samples to the standard curve.
DETECTION RANGE
1.2 ng/ml-300 ng/ml. The standard curve concentrations used for
the ELISA’s were 300 ng/ml, 75 ng/ml, 18.75 ng/ml, 4.69 ng/ml,
1.2 ng/ml.
SPECIFICITY
This assay recognizes recombinant and natural rat ADMA. No
significant cross-reactivity or interference was observed.
3
SENSITIVITY
The minimum detectable dose of rat ADMA is typically less than
0.75 ng/ml. The sensitivity of this assay, or Lower Limit of
Detection (LLD) was defined as the lowest protein concentration
that could be differentiated from zero.
MATERIALS PROVIDED
Reagent Quantity
Assay plate 1
Standards (S1-S5) 5 x 0.5 ml
HRP-conjugate 1 x 6 ml
Antibody 1 x 6 ml
Wash Buffer
1 x 15 ml
(20×concentrate)
Substrate A 1 x 7 ml
Substrate B 1 x 7 ml
Stop Solution 1 x 7 ml
Standard S1 S 2 S3 S4 S5
Concentration
(ng/ml) 1.2 4.69 18.75 75 300
4
STORAGE
1. Unopened test kits should be stored at 2-8°C upon receipt
and the microtiter plate should be kept in a sealed bag. The
test kit may be used throughout the expiration date of the kit,
provided it is stored as prescribed above. Refer to the
package label for the expiration date.
2. Opened test plate should be stored at 2-8°C in the aluminum
foil bag with desiccants to minimize exposure to damp air. The
kits will remain stable until the expiring date shown, provided it
is stored as prescribed above.
3. A microtiter plate reader with a bandwidth of 10 nm or less
and an optical density range of 0-3 OD or greater at 450nm
wavelength is acceptable for use in absorbance
measurement.
REAGENT PREPARATION
1. Bring all reagents and plate to room temperature for at least
30 minutes before use. Unused wells need store at 2-8℃and
avoid sunlight.
5
2. Wash Buffer If crystals have formed in the concentrate,
warm to room temperature and mix gently until the crystals
have compley dissolved. Dilute 15 ml of Wash Buffer
Concentrate into deionized or distilled water to prepare 300 ml
of Wash Buffer.
Precaution: The Stop Solution provided with this kit is an acid solution. Wear
eye, hand, face, and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
Microplate reader capable of measuring absorbance at 450
nm, with the correction wavelength set at 540 nm or 570 nm.
Pipettes and pipette tips.
Deionized or distilled water.
Squirt bottle, manifold dispenser, or automated microplate
washer.
An incubator which can provide stable incubation conditions
up to 37°C±0.5°C.
SAMPLE COLLECTION AND STORAGE
Serum Use a serum separator tube (SST) and allow
samples to clot for 30 minutes before centrifugation for 15
6
minutes at 1000 g. Remove serum and assay immediay or
aliquot and store samples at -20°C. Centrifuge the sample
again after thawing before the assay. Avoid repeated
freeze-thaw cycles.
Plasma Collect plasma using citrate, EDTA, or heparin as
an anticoagulant. Centrifuge for 15 minutes at 1000 g within
30 minutes of collection. Assay immediay or aliquot and
store samples at -20°C. Centrifuge the sample again after
thawing before the assay. Avoid repeated freeze-thaw cycles.
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is
recommended that all samples, standards, and controls be assayed in duplicate.
All the reagents should be added directly to the liquid level in the well. The
pipette should avoid contacting the inner wall of the well.
1. Set a Blank well without any solution. Add 50μl of Standard or
Sample per well. Standard need test in duplicate.
2. Add 50μl of HRP-conjugate to each well (not to Blank well),
then 50μl Antibody to each well. Mix well and then incubate
for 1 hour at 37°C.
7
3. Fill each well with Wash Buffer (about 200μl), stay for 10
seconds and Spinning. Repeat the process for a total of three
washes. Complete removal of liquid at each step is essential
to good performance. After the last wash, remove any
remaining Wash Buffer by aspirating or decanting. Invert the
plate and blot it against clean paper towels.
4. Add 50μl of Substrate A and 50μl Substrate B to each well,
mix well. Incubate for 15 minutes at 37°C. Keeping the plate
away from drafts and other temperature fluctuations in the
dark.
5. Add 50μl of Stop Solution to each well. If color change does
not appear uniform, gently tap the plate to ensure thorough
mixing.
6. Determine the optical density of each well within 10 minutes,
using a microplate reader set to 450 nm.
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a standard curve is
recommended, which can be downloaded from our web.
Average the duplicate readings for each standard, Blank, and
sample and subtract the optical density of Blank. Create a
8
standard curve by reducing the data using computer software
capable of generating a four parameter logistic (4-PL) curve-fit.
As an alternative, construct a standard curve by plotting the
mean absorbance for each standard on the y-axis against the
concentration on the x-axis and draw a best fit curve through the
points on the graph. The data may be linearized by plotting the
log of the ADMA concentrations versus the log of the O.D. and
the best fit line can be determined by regression analysis. This
procedure will produce an adequate but less precise fit of the
data. If samples have been diluted, the concentration read from
the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
The kit should not be used beyond the expiration date on the
kit label.
Do not mix or substitute reagents with those from other lots or
sources.
If samples generate values higher than the highest standard,
dilute the samples with the appropriate Diluent and repeat the
assay.
9
Any variation in operator, pipetting technique, washing
technique, incubation time or temperature, and kit age can
cause variation in binding.
This assay is designed to eliminate interference by soluble
receptors, binding proteins, and other factors present in
biological samples. Until all factors have been tested in the
Quantikine Immunoassay, the possibility of interference
cannot be excluded.
TECHNICAL HINTS
Centrifuge vials before opening to collect contents.
To avoid cross-contamination, change pipette tips between
additions of each standard level, between sample additions,
and between reagent additions. Also, use separate reservoirs
for each reagent.
When using an automated plate washer, adding a 30 second
soak period following the addition of wash buffer, and/or
rotating the plate 180 degrees between wash steps may
improve assay precision.
To ensure accurate results, proper adhesion of plate sealers
during incubation steps is necessary. Sealers can not be
reused.
10
Substrate Solution should remain colorless or light blue until
added to the plate. Keep Substrate Solution protected from
light. Substrate Solution should change from colorless or light
blue to gradations of blue.
Stop Solution should be added to the plate in the same order
as the Substrate Solution. The color developed in the wells will
turn from blue to yellow upon addition of the Stop Solution.
Wells that are green in color indicate that the Stop Solution
has not mixed thoroughly with the Substrate Solution.

廈門慧嘉生物長期專業銷售ELISA試劑盒\AssayBiotech\Santa \BD\Immunoway\ Abcam \ Cst \ jackson \ Pierce \ Sigma \ Amresco \Qiagen \ Cayman \ abnova \ millipore \ invitrogen \ merk \ ebioscience \prospec \ peprotech細胞因子*。等生物試劑產品。實驗為大,誠信經營,為客戶提供zui高質量的產品zui的服務

    

:

登陸向客服人員索取原版說明書。

歡迎廣大老師來詢!


環保在線 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.kindlingtouch.com,All rights reserved.

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,環保在線對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
主站蜘蛛池模板: 班戈县| 苍梧县| 那曲县| 屯昌县| 开封市| 临洮县| 邹城市| 万盛区| 磐安县| 武川县| 霞浦县| 河东区| 承德市| 安西县| 北安市| 梧州市| 新源县| 碌曲县| 宿迁市| 信宜市| 竹北市| 凤山市| 德安县| 同仁县| 石屏县| 玉门市| 清原| 万年县| 右玉县| 乌兰浩特市| 昌黎县| 咸宁市| 探索| 伊吾县| 安阳县| 石渠县| 博兴县| 资溪县| 宜昌市| 木兰县| 阿拉善盟|