污水處理設(shè)備 污泥處理設(shè)備 水處理過(guò)濾器 軟化水設(shè)備/除鹽設(shè)備 純凈水設(shè)備 消毒設(shè)備|加藥設(shè)備 供水/儲(chǔ)水/集水/排水/輔助 水處理膜 過(guò)濾器濾芯 水處理濾料 水處理劑 水處理填料 其它水處理設(shè)備
廣州乘方自動(dòng)化設(shè)備有限公司銷售部
參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地廣州市
聯(lián)系方式:陽(yáng)(先生)查看聯(lián)系方式
更新時(shí)間:2015-06-17 14:14:49瀏覽次數(shù):246次
聯(lián)系我時(shí),請(qǐng)告知來(lái)自 環(huán)保在線通訊接口:
RS-232C,Dsub25銷,1端口(ACM11)
RS-422 / RS-485,6極接線端子,1個(gè)端口(ACM12)
連接方式:
點(diǎn)對(duì)點(diǎn)的MODEM連接可能的(RS-232C / RS-422)
點(diǎn)對(duì)點(diǎn)/多點(diǎn)(RS-485)
Models SFE2210, SFH2210,SFE2261, SFH2261FCS Subsystem Communication Functions
The Field Control Station (FCS) can communicate with subsystems such as sequencers, via the communication modules installed in the nodes. The FCS computates and controls acquired subsystem data. The GS describes the following subsystem communication packages.
? Models SFE2210,SFH2210
FA500/FA-M3 Communication Packages
? Models SFE2261,SFH2261
MELSEC-A Communication Packages
Please note that software with different release numbers (software version) cannot be combined on CENTUM CS.The Release No. is described as R _ .
1. Subsystem Communication Specifications
Communication with Function Blocks
Subsystem data is stored in the PI/O image portion of Model ACM11 or ACM12 and sent to the data area of the FCS via RIO bus communication. The subsystem data is connected to the function block I/O terminals, like general analog or digital I/O signals.
? Subsystem Connection Specification
The subsystem is connected via the ACM11, ACM12 communication module installed in the FCS node.
No. of ACM11, ACM12 Modules: 6 modules per FCS
No. of subsystem types for communication:6 types per FCS
No. of digital I/O data for communication:Max. 4,096 data per FCS (including I/O signals of FCS)
Models ACM11, ACM12
Communication Module Specifications
Data volume for communication:Max. 500 words per ACM1_ (1 word = 16 bit)
Digital I/O data for communication: Max. 3,840 data per ACM1_
No. of subsystems for communication:Max. 30 subsystems
Communication interface:
RS-232C, Dsub25 pins, 1 port (ACM11)
RS-422/RS-485, 6 pole terminal block, 1 port(ACM12)
Connection method:
Point-to-point MODEM connection possible(RS-232C/RS-422)
Point-to-point/Multipoint (RS-485)
Synchronization method:
Start-stop synchronization
Transmission dpeed:
1,200, 2,400, 4,800, 9,600, 19,200 bit per sec.
2. Models SFE2210, SFH2210
FA500/FA-M3 Communication Packages
Connector: Personal Computer Link Module
FA500: LC01-0N, LC02-0N
FA-M3: F3LC11-1N, F3LC11-2N
Connection: A Personal Computer Link Module is connected with ACM11 or ACM12 communication port.
Devices for Communication: FA500, FA-M3 (max 30 station)
Transmission Protocol: Dedicated Control Protocol
Internal Data for Communication:
Bit Device: input relay, output relay, internal relay, common relay, link relay, special relay, time-up relay, count-up relay
Word Device: decrementing timer current value, incrementing timer current value, timer set value, decrementing counter current value, incrementing counter current value, counter set value, data register, common register, shared register, index register, link register,special register
Special Device: communication time, communication status
Communication Capacity:
Bit Device: 8 words
Word Device: 64 words
3. Models SFE2261,SFH2261
MELSEC-A Communication Packages
Connector: MELSEC-A Computer Link Unit
AJ71C24-S8,-S6,-S3, AJ71UC24,
A1SJ71C24-R2, -R4, -PRF, A1SCPUC24-R2,
A2CCPUC24, A2CCPUC24-PRF
Connection: One-to-one connection between the ACM11,
ACM12 Communication Port and Computer
Link Unit
Devices for Communication: MELSEC-A CPU Unit
A0J2H, A1, A1N, A1S, A1SJ, A2(-S1),
A2N(-S1), A2S, A2C, A52G, A2U(-S1),
A2US(-S1), A3, A3N, A3H, A3M, A73,
A2A(-S1), A3A, A3U, A4U, A7LMS-F
Transmission Protocol: MELSEC-A Dedicated Control
Protocol Format 4
Internal Data for Communication:
Bit Device: bit I/O, internal relay, latch relay, step relay,
link relay, annunciator, special relay, timer
(contact), timer (coil), counter (contact),
counter (coil)
Word Device: timer (current value), counter (current
value), data register, link register, file
register, special register
Special Device: communication status
Communication Capacity:
Max. data per communication:
Read: 8 points (bit device), 64 points (word device)
Write: 8 points (bit device), 64 points (word device)
4. Engineering for Subsystem Communication
The subsystem communication function is generated by
using the FCS Builder Maintenance Package (Model
SHW5120).
? Hardware Requirements
FCS Models: AFE10S,AFE10D,AFE20S,AFE20D
AFM10S,AFM10D,AFM20S,AFM20D
AFS10S,AFS10D,AFS20S,AFS20D
? Software Requirements
It operates on the Field Control Station Standard Control
Functions (Models SFE1100,SFH1100).
Description | ||
Models | SFE2210 | FA500/FA-M3 Communication Package (for AFE___ AFM___) |
SFH2210 | FA500/FA-M3 Communication Package (for AFS___) | |
Suffix Codes | -S | Basic Software License |
-C | Multiple Software License (for 2 or more) | |
1 | Always 1 | |
1 | English-Language Version |
Description | ||
Models | SFE2261 | MELSEC-A Communication Package (for AFE___ AFM___) |
SFH2261 | MELSEC-A Communication Package (for AFS___) | |
Suffix Codes | -S | Basic Software License |
-C | Multiple Software License (for 2 or more) | |
1 | Always 1 | |
1 | English-Language Version |
? Specify model and suffix code.
? When ordering separay from HP9000 series 700, specify its hardware’s ID number.
? MELSEC-A is a registered trademark of Mitsubishi Electric Corporation.
? All other company names and product names mentioned in this GS are trademarks or registered trademarks of the respective companies.
您感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN
商鋪:http://www.kindlingtouch.com/st153170/
主營(yíng)產(chǎn)品:現(xiàn)場(chǎng)儀表,控制器,記錄儀,數(shù)據(jù)采集儀器,生產(chǎn)控制儀器,環(huán)境分析儀表,DCS系統(tǒng)卡件,電子測(cè)量?jī)x器.
環(huán)保在線 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ?
請(qǐng)輸入賬號(hào)
請(qǐng)輸入密碼
請(qǐng)輸驗(yàn)證碼
請(qǐng)輸入你感興趣的產(chǎn)品
請(qǐng)簡(jiǎn)單描述您的需求
請(qǐng)選擇省份
聯(lián)系方式
廣州乘方自動(dòng)化設(shè)備有限公司銷售部