High Voltage Probes
上海鉑鱗貿易有限公司
:王昊強
:
:whq@berling.com.cn
美國NORTH STAR高壓探頭,PVM系列,VD系列
High voltage measurements have a variet
y of different requirements, and our PVM series and VD series probes are designed for most of these requirements. The PVM probes are designed for wide bandwidth and ease of portability where a variety of measurements must be made. The VD series probes are designed for use at higher voltage ranges, and where physical stability is required.
PVM series probes with PVM-5 on top and PVM-10 on the bottom
The design of the probes is unique. The probe comes fully adjusted without any requirement to further adjust the probe in the field. Stray capacitances internal to the probe are factory calibrated. Stray capacitances due to proximity effects are minimized by the unique conductor placement.
Low temperature and voltage coefficient resistors and capacitors are used throughout the probe to provide maximum measurement accuracy. The probe has a rugged nylon housing, and it is filled with dielectric oil for maximum high voltage stability.
Our PVM Series probes our available with either 1000:1 or 2000:1 calibration factors at the time of order.
Voltage Probe Specifications
PVM Series Portable High Voltage Probes to 60 kV DC
PVM series high voltage probes are designed for general use, and for exceptional high frequency response. The probes have applications ranging from automotive ignition to excimer laser system measurement to EMI measurement. They are factory calibrated, and they do not require adjustment. In general the probes are for use with 1 Megohm oscilloscopes, but we also offer an optional switch which can compensate for various measurement instruments such as 10 Megohm meters as well. These units are intended for a wide range of applications where portability and ease of use are essential.
Model Number | PVM-1 | PVM-2 | PVM-3 | PVM-4 | PVM-5 | PVM-6 | PVM-11 (PVM-10) | PVM-12 |
---|---|---|---|---|---|---|---|---|
Max DC/Pulsed V (kV) | 40/60 | 40/60 | 40/60 | 40/60 | 60/100 | 60/100 | 10/12 | 25/30 |
Max Frequency (Mhz.) | 80 | 80 | 40 | 110 | 80 | 80 | 50 | 80 |
Cable Impedance (ohms) | 50 | 50 | 50 | 93 | 50 | 50 | 50 | 50 |
DC - 2 Hz.accuracy | <0.1% | <0.1% | <0.1% | <0.1% | <0.1% | <0.1% | <0.1% | <0.1% |
2 Hz. - 200 Hz. accuracy | <1 % | <1. % | <2. % | <1. % | <1 % | <1 % | <1.5 % | <1.5 % |
200 Hz. - 5 Mhz. accuracy | <1.5% | <1.5% | <3% | <1.5% | <1.5% | <1.5% | <2.% | <2.% |
> 5 Mhz. Accuracy | <3% | <3% | <4% | <5% | <3% | <4% | <4% | <4% |
Input R/C (Megohm/pf) | 400/13 | 400/13 | 400/10 | 400/10 | 400/12 | 400/12 | 100(50)/15 | 300/7 |
Cable Length (ft./m) | 15/4.5 | 30/9 | 100/30 | 15/4.5 | 15/4.5 | 30/9 | 15/4.5 | 15/4.5 |
Standard Divider Ratio | 1000:1 | 1000:1 | 10,000:1 | 1000:1 | 1000:1 | 1000:1 | 1000:1 (100:1) | 1000:1 |
Length (inches/cm.) | 19/47 | 19/47 | 19/47 | 19/47 | 19/47 | 19/47 | 7/18 | 9/23 |
Add -2 to any PVM-1 - PVM-6 or PVM-12 part number for 2000:1 ratio
VD Series High Voltage Probes 60 to 300 kV DC
VD series high voltage probes are floor standing high voltage probes which are designed for rugged day in - day out use. They are used in a wide range of applications ranging from evision tube manufacturing to radar to advanced particle accelerator applications. Resistors with an extremely low voltage coefficient of resistance are used, and all capacitors are temperature, frequency, and voltage stabilized for the best possible performance. The probes all have field defining toroids as a standard item in order to minimize the proximity effect (stray capacitance) and maximize the reproducibility of the measurement. The high and low frequency calibrations are carefully matched before shipment. Very high frequency cable effects are also carefully compensated so accurate measurements can be made even when the cable length exceeds the pulse duration. No adjustments are necessary once the probes have been factory calibrated.
Model Number | VD-60 | VD-100 | VD-150 | VD-200 | VD-300 | VD-400 |
---|---|---|---|---|---|---|
Max DC/Pulsed V (kV) | 60/120 | 100/180 | 150/240 | 200/300 | 300/420 | 400/550 |
Max Frequency (Mhz.) | 20 | 20 | 20 | 16 | 12 | 8 |
Cable Length (ft.) | 30 | 30 | 30 | 30 | 30 | 30 |
DC accuracy | <0.1% | <0.1% | <0.1% | <0.1% | <0.1% | <0.1% |
10 Hz. - 1 Mhz. Accuracy | 1 % | 1 % | 1 % | 2 % | 2.5 % | 3 % |
>1 Mhz Accuracy | 3 % | 3 % | 3 % | 3 % | 4 % | 4 % |
Resistance (Megohms) | 800 | 1600 | 2000 | 2800 | 4500 | 7000 |
Height (inches/cm.) | 20/50 | 24/60 | 30/75 | 40/99 | 54/135 | 72/180 |
Diameter (in/cm.) | 11/28 | 11/28 | 12/29 | 16/40 | 24/61 | 24/61 |
Capacitance (approx. pf) | 27 | 25 | 27 | 24 | 20 | 16 |
Base Diameter(in/cm.) | 10/25 | 10/25 | 12/30 | 20/50 | 30/76* | 30/76 |
Standard Divider Ratio | 10,000:1 | 10,000:1 | 10,000:1 | 10,000:1 | 10,000:1 | 10,000:1 |
Voltage Probe Outline Drawings
Pulsed Power Formulary (794 KB)
Bare Probe Manual (345 KB)
PVM 1-4 Outline (32 KB)
PVM 5-6 Outline (31 KB)
PVM-10/11 Outline (22 KB)
PVM-12 Outline (28 KB)
VD-100 Outline (11 KB)
VD-150 Outline (5 KB)
VD-200 Outline (6 KB)
VD-300 Outline (4 KB)
VD-60 Outline (10 KB)
相關產品
- 美國Transducer美國Transducer 資料
- 美國Transducer美國Transducer
- 美國Scientech美國Scientech
- 意大利VESTA意大利VESTA
- 法國01-db Metravib法國01-db Metravib
- DIXONDIXON
- 美國DIXON美國DIXON
- 德國LUMBERG德國LUMBERG型號
- 德國LUMBERG德國LUMBERG
- 美國DYNISCO美國DYNISCO資料
- 美國HEVI-DUTY美國HEVI-DUTY
- 美國SOLA美國SOLA
- 英國 michelle英國 michelle
- HAINZLHAINZL
- 美國Alta-Robbins美國Alta-Robbins代理
- LUMASENSE測溫計LUMASENSE測溫計
- SMW-Autoblok卡盤SMW-Autoblok卡盤
- 法國 MEGATRON法國 MEGATRON
- 德國BICKER德國BICKER
- 美國Hammond美國Hammond
- 瑞士WYLER瑞士WYLER
- 德國HUNGER德國HUNGER
- 美國 Metrix美國 Metrix
- 意大利 CARLO意大利 CARLO
- 德國 RAJA德國 RAJA
- 德國RINCK電源德國RINCK電源
- 德國RINCK ELECTRONIC德國RINCK ELECTRONIC
- 德國PINTSCH BUBENZER德國PINTSCH BUBENZER
- 德國MURR德國MURR
- Mid-WestMid-West
- FORNEYFORNEY
- 美國CASHCO美國CASHCO
- 德國RITTAL德國RITTAL
- 美國black box美國black box
- 阿泰克AI-TEK阿泰克AI-TEK
- 英國bulgin英國bulgin
- 英國海矩hi-force英國海矩hi-force
- 德國Ott GmbH德國Ott GmbH
- 瑞典 INOR瑞典 INOR
- 美國FAIRCHILD美國FAIRCHILD