美國NORTH STAR PVM VD系列

【詳細說明】

High Voltage Probes

上海鉑鱗貿易有限公司
:王昊強
: 
     

 
:whq@berling.com.cn

美國NORTH STAR高壓探頭,PVM系列,VD系列

High voltage measurements have a variet

y of different requirements, and our PVM series and VD series probes are designed for most of these requirements. The PVM probes are designed for wide bandwidth and ease of portability where a variety of measurements must be made. The VD series probes are designed for use at higher voltage ranges, and where physical stability is required.

Specialty ProbesPVM series probes with PVM-5 on top and PVM-10 on the bottom

The design of the probes is unique. The probe comes fully adjusted without any requirement to further adjust the probe in the field. Stray capacitances internal to the probe are factory calibrated. Stray capacitances due to proximity effects are minimized by the unique conductor placement.

Low temperature and voltage coefficient resistors and capacitors are used throughout the probe to provide maximum measurement accuracy. The probe has a rugged nylon housing, and it is filled with dielectric oil for maximum high voltage stability.

Our PVM Series probes our available with either 1000:1 or 2000:1 calibration factors at the time of order.

Voltage Probe Specifications

PVM Series Portable High Voltage Probes to 60 kV DC

PVM series high voltage probes are designed for general use, and for exceptional high frequency response. The probes have applications ranging from automotive ignition to excimer laser system measurement to EMI measurement. They are factory calibrated, and they do not require adjustment. In general the probes are for use with 1 Megohm oscilloscopes, but we also offer an optional switch which can compensate for various measurement instruments such as 10 Megohm meters as well. These units are intended for a wide range of applications where portability and ease of use are essential.

Model NumberPVM-1PVM-2PVM-3PVM-4PVM-5PVM-6PVM-11 (PVM-10)PVM-12
Max DC/Pulsed V (kV)40/6040/6040/6040/6060/10060/10010/1225/30
Max Frequency (Mhz.)80804011080805080
Cable Impedance (ohms)5050509350505050
DC - 2 Hz.accuracy<0.1%<0.1%<0.1%<0.1%<0.1%<0.1%<0.1%<0.1%
2 Hz. - 200 Hz. accuracy<1 %<1. %<2. %<1. %<1 %<1 %<1.5 %<1.5 %
200 Hz. - 5 Mhz. accuracy<1.5%<1.5%<3%<1.5%<1.5%<1.5%<2.%<2.%
> 5 Mhz. Accuracy<3%<3%<4%<5%<3%<4%<4%<4%
Input R/C (Megohm/pf)400/13400/13400/10400/10400/12400/12100(50)/15300/7
Cable Length (ft./m)15/4.530/9100/3015/4.515/4.530/915/4.515/4.5
Standard Divider Ratio1000:11000:110,000:11000:11000:11000:11000:1 (100:1)1000:1
Length (inches/cm.)19/4719/4719/4719/4719/4719/477/189/23

Add -2 to any PVM-1 - PVM-6 or PVM-12 part number for 2000:1 ratio

VD Series High Voltage Probes 60 to 300 kV DC

Specialty Probes

VD series high voltage probes are floor standing high voltage probes which are designed for rugged day in - day out use. They are used in a wide range of applications ranging from evision tube manufacturing to radar to advanced particle accelerator applications. Resistors with an extremely low voltage coefficient of resistance are used, and all capacitors are temperature, frequency, and voltage stabilized for the best possible performance. The probes all have field defining toroids as a standard item in order to minimize the proximity effect (stray capacitance) and maximize the reproducibility of the measurement. The high and low frequency calibrations are carefully matched before shipment. Very high frequency cable effects are also carefully compensated so accurate measurements can be made even when the cable length exceeds the pulse duration. No adjustments are necessary once the probes have been factory calibrated.

Model NumberVD-60VD-100VD-150VD-200VD-300VD-400
Max DC/Pulsed V (kV)60/120100/180150/240200/300300/420400/550
Max Frequency (Mhz.)20202016128
Cable Length (ft.)303030303030
DC accuracy<0.1%<0.1%<0.1%<0.1%<0.1%<0.1%
10 Hz. - 1 Mhz. Accuracy1 %1 %1 %2 %2.5 %3 %
>1 Mhz Accuracy3 %3 %3 %3 %4 %4 %
Resistance (Megohms)80016002000280045007000
Height (inches/cm.)20/5024/6030/7540/9954/13572/180
Diameter (in/cm.)11/2811/2812/2916/4024/6124/61
Capacitance (approx. pf)272527242016
Base Diameter(in/cm.)10/2510/2512/3020/5030/76*30/76
Standard Divider Ratio10,000:110,000:110,000:110,000:110,000:110,000:1

Voltage Probe Outline Drawings

Pulsed Power Formulary (794 KB)

Bare Probe Manual (345 KB)

PVM 1-4 Outline (32 KB)

PVM 5-6 Outline (31 KB)

PVM-10/11 Outline (22 KB)

PVM-12 Outline (28 KB)

VD-100 Outline (11 KB)

VD-150 Outline (5 KB)

VD-200 Outline (6 KB)

VD-300 Outline (4 KB)

VD-60 Outline (10 KB)

    
留言框
感興趣的產品: *
留言內容:
您的姓名: *
您的單位:
聯系電話: *
微信:
常用郵箱:
詳細地址:
省份: *
驗證碼: * =   請輸入計算結果(填寫阿拉伯數字),如:三加四=7
是否接受其他廠商報價: *
      
產品搜索

請輸入產品關鍵字:

聯系方式
地址:浙江省杭州市西湖區文二路319號西湖國際科技大廈5號樓中區3樓
郵編:310012
聯系人:采購部
留言:在線留言
商鋪:http://www.kindlingtouch.com/st133537/
| 商鋪首頁 | 公司檔案 | 產品展示 |公司動態 | 詢價留言 | 聯系我們 | 會員管理 |
環保在線 設計制作,未經允許翻錄必究.Copyright(C) http://www.kindlingtouch.com, All rights reserved.
以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,環保在線對此不承擔任何保證責任。
溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。
二維碼

掃一掃訪問手機站
主站蜘蛛池模板: 简阳市| 青龙| 唐山市| 故城县| 资阳市| 徐州市| 南澳县| 斗六市| 桃江县| 内江市| 合江县| 昭苏县| 大洼县| 吴川市| 潜江市| 翁牛特旗| 灵石县| 丹寨县| 新和县| 类乌齐县| 巴南区| 大悟县| 乐东| 泰兴市| 抚州市| 盖州市| 搜索| 垣曲县| 津市市| 拜泉县| 富川| 聊城市| 蒙自县| 河东区| 连山| 左云县| 荔浦县| 武夷山市| 增城市| 和顺县| 阳原县|