日韩午夜在线观看,色偷偷伊人,免费一级毛片不卡不收费,日韩午夜在线视频不卡片

產(chǎn)品|公司|采購(gòu)|招標(biāo)

廣電計(jì)量檢測(cè)集團(tuán)股份有限公司

100Gb/s QSFP28 ZR4 BIDI 80km Transceiver

參考價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 公司名稱廣州市瑞東電子科技有限公司
  • 品       牌
  • 型       號(hào)
  • 所  在  地廣州市
  • 廠商性質(zhì)其他
  • 更新時(shí)間2024/11/21 9:33:40
  • 訪問次數(shù)79
產(chǎn)品標(biāo)簽:

在線詢價(jià)收藏產(chǎn)品 點(diǎn)擊查看電話
FIBERWDM為廣州市瑞東電子科技有限公司創(chuàng)建并注冊(cè)的品牌商標(biāo),成立于2011年。瑞東是一家專業(yè)從事于研發(fā)、生產(chǎn)和銷售光纖通信設(shè)備和器件的高科技企業(yè)。公司以市場(chǎng)和用戶需求為產(chǎn)品開發(fā)與設(shè)計(jì)的先導(dǎo),不斷推出性能、價(jià)格競(jìng)爭(zhēng)力強(qiáng)的新產(chǎn)品,其產(chǎn)品種類豐富,立足于自身的研發(fā)和實(shí)力,產(chǎn)品線已涵蓋從光器件和光通信設(shè)備,產(chǎn)品包括光收發(fā)模塊,光無(wú)源器件,CWDM設(shè)備、DWDM設(shè)備,光保護(hù)設(shè)備,光纖放大器,網(wǎng)絡(luò)分流器,分光設(shè)備,光纖鏈路監(jiān)測(cè)等在內(nèi)的十多個(gè)系列,能夠滿足數(shù)據(jù)中心,網(wǎng)絡(luò)信息安全,,,電力,高校和科研院所,安防,交通,金融,教育,能源等各行各業(yè)多方面的應(yīng)用需求,為用戶提供多種可選擇的全面解決方案,產(chǎn)品可靠性高、環(huán)境適應(yīng)能力強(qiáng)、質(zhì)量穩(wěn)定,受到用戶的廣泛好評(píng),穩(wěn)步上升。公司以技術(shù)創(chuàng)新為企業(yè)生存和發(fā)展的根本,始終重視保持核心技術(shù)優(yōu)勢(shì)。
管理型交換機(jī)
Features Support line rates from 103.125 Gb/s to 112.2 Gb/s OTU4Built-in 4-channel Clock and Data Recovery (CDR) in TX and RXLAN WDM EML laser and PIN receiver with SOAUp to 80km reach ......
100Gb/s QSFP28 ZR4 BIDI 80km Transceiver 產(chǎn)品信息


100Gb/s QSFP28 ZR4 BIDI 80km Transceiver

RQ-100GBD80-A/RQ-100GBD80-B


100Gb/s QSFP28 ZR4 BIDI 80km Transceiver



FIBERWDM’ RQ-100GBD80-A/RQ-100GBD80-B is designed for 100G 80km single fiber optical communication applications. This module contains 4-lane optical transmitter, 4-lane optical receiver and module management block including 2 wire serial inter-face. The optical signals are multiplexed to a single-mode fiber through an industry standard LC connector. A block diagram is shown in Figure 1.




Electrical Characteristics

The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified.

 

Parameter

Symbol

Min.

Typ.

Max

Unit

Notes

Power Consumption

p

 

 

5.5

W

 

Supply Current

Icc

 

 

1585

mA

 


Transmitter (each Lane)

Input differential impedance

Rin

 

100

 

Ω

 

Differential Termination Mismatch

 

 

 

10

%

 

Differential Data Input Amplitude

Vin, PP

180

 

1000

mV

 

LPMode, Reset and ModSelL

VIL

-0.3

 

0.8

V

 

VIH

2

 

Vcc+0.3

V

 

Receiver

Differential Data Output Amplitude

Vout, PP

350

 

900

mV

 

Differential Termination Mismatch

 

 

 

10

%

 

Transition Time, 20 to 80%

 

9.5

 

 

ps

 

ModPrsL and IntL

VOL

0

 

0.4

V

 

VOH

Vcc-0.5

 

Vcc+0.3

V

 



Optical Characteristics

The following optical characteristics are defined over the Recommended Operating Environment unless otherwise specified.


Parameter

Symbol

Min.

Typical

Max

Unit

Notes

Transmitter

Lane wavelength(range)

RQ-100GBD80-A

L0

1272.55

1273.55

1274.54

nm

 

L1

1276.89

1277.89

1278.89

nm

 

L2

1281.25

1282.26

1283.27

nm

 

L3

1285.65

1286.66

1287.68

nm

 

RQ-100GBD80-B

L4

1294.53

1295.56

1296.59

nm

 

L5

1299.02

1300.05

1301.09

nm

 

L6

1303.54

1304.58

1305.63

nm

 

L7

1308.09

1309.14

1310.09

nm

 

Signaling rate, each lane

 

 

25.78125

28.05

Gb/s

 

Side-mode suppression ratio

SMSR

30

 

 

 

 

Total launch power

PT

8.0

 

10.5

dBm

 

Average launch power, each lane

Pavg

2.0

 

4.5

dBm

 

Extinction Ratio

ER

6.0

 

 

dB

 

Difference in Launch Power between any Two Lanes (OMA)

Ptx,diff

 

 

3.6

dB

 

Average launch power of OFF transmitter, each lane

Poff

 

 

-30

dBm

 

Transmitter reflectance

RT

 

 

-12

dB

 

RIN20OMA

RIN

 

 

-130

dB/Hz

 

Optical Return Loss Tolerance

TOL

 

 

20

dB

 

Transmitter eye mask {X1, X2, X3, Y1, Y2, Y3}

 

{0.25, 0.4, 0.45, 0.25, 0.28, 0.4}

 

 

Receiver

Lane wavelength(range)

RQ-100GBD80-A

 

L0

1294.53

1295.56

1296.59

nm

 

L1

1299.02

1300.05

1301.09

nm

 

L2

1303.54

1304.58

1305.63

nm

 

L3

1308.09

1309.14

1310.09

nm

 

RQ-100GBD80-B

L4

1272.55

1273.55

1274.54

nm

 

L5

1276.89

1277.89

1278.89

nm

 

L6

1281.25

1282.26

1283.27

nm

 

L7

1285.65

1286.66

1287.68

nm

 

Signaling rate, each lane

 

 

25.78125

28.05

Gb/s

 

Average Receive Power, each Lane

 

-30

 

-7

dBm

 

Receive Power (OMA), each Lane

 

 

 

-7

dBm

 

Receiver reflectance

 

 

 

-26

dB

 

Receiver sensitivity Average, each lane

SEN1

 

 

-22

dBm

1

SEN2

 

 

-21

dBm

2

SEN3

 

 

-28

dBm

3

SEN4

 

 

-27

dBm

4

LOS Assert

LOSA

-40

 

 

dBm

 

LOS Deassert

LOSD

 

 

-29

dBm

 

LOS Hysteresis

LOSH

0.5

 

 

dB

 

Notes:

1. Measured @25.78125Gbps, ER=8.2dB, BER=<1E-12, PRBS=231-1 NRZ

2. Measured @28.05Gbps, ER=8.2dB, BER=<1E-12, PRBS=231-1 NRZ

3. Measured @25.78125Gbps, ER=8.2dB, BER=<5E-5, PRBS=231-1 NRZ

4. Measured @28.05Gbps, ER=8.2dB, BER=<5E-5, PRBS=231-1 NRZ



Digital Diagnostic Functions

The following digital diagnostic characteristics are defined over the normal operating conditions unless otherwise specified.


Parameter

Symbol

Min.

Max

Unit

Range

Temperature monitor absolute error

DMI_ Temp

-3

3

oC

-40~85C

Supply voltage monitor absolute error

DMI _VCC

-3

3

%

0~Vcc

RX power monitor absolute error

DMI_RX

-3

3

dB

-7~-30dBm

Bias current monitor error

DMI_ bias

-10

10

%

0~120mA

TX power monitor absolute error

DMI_TX

-3

3

dB

2~4.5dBm

 

 

Absolute Maximum Ratings

It has to be noted that the operation in excess of any individual absolute maximum ratings might cause permanent damage to this module. 


Parameter

Symbol

Min

Max

Unit

Notes

Storage Temperature

TS

-40

85

oC

 

Power Supply Voltage

VCC

-0.3

4.0

V

 

Relative Humidity (non-condensation)

RH

15

85

%

 

Damage Threshold

THd

6.5

 

dBm

 



Recommended Operating Conditions


Parameter

Symbol

Min

Typical

Max

Unit

Notes

Operating Case Temperature

TOP

0

 

70

oC

Commercial

-5

 

85

oC

Extended

-40

 

85

oC

Industrial

Power Supply Voltage

VCC

3.135

3.3

3.465

V

 

Data Rate, each Lane

 

 

25.78125

28.05

Gb/s

 

Control Input Voltage High

 

2

 

Vcc

V

 

Control Input Voltage Low

 

0

 

0.8

V

 

Link Distance (SMF)

D

 

 

80

km

1

Notes:

1. Depending on actual fiber loss/km (link distance specified is for fiber insertion loss of 0.35dB/km)



ModSeIL

The ModSelL is an input pin. When held low by the host, the module responds to 2-wire serial communication commands. The ModSelL allows the use of multiple modules on a single 2-wire interface bus. When the ModSelL is "High", the module shall not respond to or acknowledge any 2-wire interface communication from the host. ModSelL signal input node shall be biased to the "High" state in the module.

In order to avoid conflicts, the host system shall not attempt 2-wire interface communications within the ModSelL de-assert time after any modules are deselected. Similarly, the host shall wait at least for the period of the ModSelL assert time before communicating with the newly selected module. The assertion and de-asserting periods of different modules may overlap as long as the above timing requirements are met.


ResetL:

The ResetL pin shall be pulled to Vcc in the module. A low level on the ResetL pin for longer than the minimum pulse length (t_Reset_init) initiates a complete module reset, returning all user module settings to their default state. Module Reset Assert Time (t_init) starts on the rising edge after the low level on the ResetL pin is released. During the execution of a reset (t_init) the host shall disregard all status bits until the module indicates a completion of the reset interrupt. The module indicates this by asserting "low" an IntL signal with the Data Not_Ready bit negated. Note that on power up (including hot insertion) the module should post this completion of reset interrupt without requiring a reset.


LPMode:

LPMode: The LPMode pin shall be pulled up to Vcc in the module. The pin is a hardware control used to put modules into a low power mode when high. By using the LPMode pin and a combination of the Power override, Power_set and High_Power_Class_Enable software control bits (Address A0h, byte 93 bits 0,1,2).


ModPrsL:

ModPrsL is pulled up to Vcc_Host on the host board and grounded in the module. The ModPrsL is asserted "Low" when inserted and deasserted "High" when the module is physically absent from the host connector.


IntL:

IntL is an output pin. When IntL is "Low", it indicates a possible module operational fault or a status critical to the host system. The host identifies the source of the interrupt using the 2-wire serial interface. The IntL pin is an open collector output and shall be pulled to host supply voltage on the host board. The INTL pin is deasserted "High" after completion of reset, when byte 2 bit 0 (Data Not Ready) is read with a value of '0' and the flag field is read .



Pin Assignment and Pin Description


 

Figure1. Diagram of host board connector block pin numbers and names 

 

 

Pin

Symbol

Name/Description

Notes

1

GND

Transmitter Ground (Common with Receiver Ground)

1

2

Tx2n

Transmitter Inverted Data Input

 

3

Tx2p

Transmitter Non-Inverted Data output

 

4

GND

Transmitter Ground (Common with Receiver Ground)

1

5

Tx4n

Transmitter Inverted Data Input

 

6

Tx4p

Transmitter Non-Inverted Data output

 

7

GND

Transmitter Ground (Common with Receiver Ground)

1

8

ModSelL

Module Select

 

9

ResetL

Module Reset

 

10

VccRx

3.3V Power Supply Receiver

2

11

SCL

2-Wire serial Interface Clock

 

12

SDA

2-Wire serial Interface Data

 

13

GND

Transmitter Ground (Common with Receiver Ground)

 

14

Rx3p

Receiver Non-Inverted Data Output

 

15

Rx3n

Receiver Inverted Data Output

 

16

GND

Transmitter Ground (Common with Receiver Ground)

1

17

Rx1p

Receiver Non-Inverted Data Output

 

18

Rx1n

Receiver Inverted Data Output

 

19

GND

Transmitter Ground (Common with Receiver Ground)

1

20

GND

Transmitter Ground (Common with Receiver Ground)

1

21

Rx2n

Receiver Inverted Data Output

 

22

Rx2p

Receiver Non-Inverted Data Output

 

23

GND

Transmitter Ground (Common with Receiver Ground)

1

24

Rx4n

Receiver Inverted Data Output

1

25

Rx4p

Receiver Non-Inverted Data Output

 

26

GND

Transmitter Ground (Common with Receiver Ground)

1

27

ModPrsl

Module Present

 

28

IntL

Interrupt

 

29

VccTx

3.3V power supply transmitter

2

30

Vcc1

3.3V power supply

2

31

LPMode

Low Power Mode

 

32

GND

Transmitter Ground (Common with Receiver Ground)

1

33

Tx3p

Transmitter Non-Inverted Data Input

 

34

Tx3n

Transmitter Inverted Data Output

 

35

GND

Transmitter Ground (Common with Receiver Ground)

1

36

Tx1p

Transmitter Non-Inverted Data Input

 

37

Tx1n

Transmitter Inverted Data Output

 

38

GND

Transmitter Ground (Common with Receiver Ground)

1

Notes:

1. GND is the symbol for signal and supply (power) common for QSFP28 modules. All are common within the QSFP28 module and all module voltages are referenced to this potential unless otherwise noted. Connect these directly to the host board signal common ground plane.

2. VccRx, Vcc1 and VccTx are the receiving and transmission power suppliers and shall be applied concurrently. Recommended host board power supply filtering is shown below. Vcc Rx, Vcc1 and Vcc Tx may be internally connected within the QSFP28 transceiver module in any combination. The connector pins are each rated for a maximum current of 1000mA.



Mechanical Dimensions


 Figure2. Mechanical Outline

 

 

Order information

Part Number

Product Description

RQ-100GBD80-A

100G QSFP28 BIDI Transceiver, TX1273.55/1277.89/1282.26/1286.66nm/ RX1295.56/1300.05/1304.58/1309.14nm, Simplex LC, 80km, 0~+70°C, with DDM

RQ-100GBD80-B

100G QSFP28 BIDI Transceiver, TX1295.56/1300.05/1304.58/1309.14nm/ RX1273.55/1277.89/1282.26/1286.66nm, Simplex LC, 80km, 0~+70°C, with DDM




15168338725
產(chǎn)品對(duì)比
QQ

咨詢中心

在線客服QQ交談

市場(chǎng)部QQ交談

發(fā)布詢價(jià)建議反饋
回到頂部

Copyright hbzhan.comAll Rights Reserved

環(huán)保在線 - 環(huán)保行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺(tái)

對(duì)比欄

提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個(gè)人信息:

主站蜘蛛池模板: 花莲县| 台东县| 济阳县| 通州区| 永康市| 徐汇区| 洮南市| 志丹县| 连山| 延吉市| 彭州市| 集安市| 临江市| 天门市| 太仆寺旗| 东源县| 延边| 江津市| 聂拉木县| 平度市| 丰顺县| 双峰县| 韩城市| 琼中| 弋阳县| 南召县| 漳浦县| 博兴县| 乌鲁木齐市| 辰溪县| 三门峡市| 罗平县| 池州市| 郓城县| 宁蒗| 湛江市| 渭南市| 安乡县| 玛纳斯县| 上犹县| 铜鼓县|