CBQ-L磁力管道離心泵
CQB-L型磁力泵型號意義
| 1 | 泵殼 | 2 | 葉輪 |
5 | 隔離套 | 6 | 止推環(huán) | |
3 | 密封環(huán) | 4 | 軸承體 | |
7 | 軸承 | 8 | 軸套 | |
11 | 螺母 | 12 | 聯(lián)接架 | |
9 | 軸 | 10 | 內(nèi)磁鋼總成 | |
13 | 外磁鋼總成 | 14 | 電機(jī) |
型號 | 進(jìn)出口經(jīng) (mm) | 流量 (m3/h) | 揚(yáng)程 (m) | 電極功率 (kw) |
25-125 | 25 | 4 | 20 | 1.5 |
25-160 | | 4 | 32 | 2.2 |
40-125 | 40 | 6.3 | 20 | 2.2 |
40-160 | 6.3 | 32 | 3 | |
40-200 | 6.3 | 50 | 5.5 | |
40-250 | 6.3 | 80 | 11 | |
50-100 | 50 | 12.5 | 12.5 | 1.5 |
50-125 | 12.5 | 20 | 3 | |
50-160 | 12.5 | 32 | 4 | |
50-200 | 12.5 | 50 | 7.5 | |
50-250 | 12.5 | 80 | 15 | |
65-100 | 65 | 25 | 12.5 | 2.2 |
65-125 | 25 | 20 | 4 | |
65-160 | 25 | 32 | 5.5 | |
65-200 | 25 | 50 | 11 | |
65-250 | 25 | 80 | 18.5 | |
80-100 | 80 | 50 | 12.5 | 4 |
80-125 | 50 | 20 | 7.5 | |
80-160 | 50 | 32 | 11 | |
80-200 | 50 | 50 | 18.5 | |
80-250 | 50 | 80 | 30 | |
100-100 | 100 | 100 | 12.5 | 75 |
100-125 | 100 | 20 | 15 | |
100-160 | 100 | 32 | 18.5 | |
100-200 | 100 | 50 | 30 | |
100-250 | 100 | 80 | 45 | |
125-125 | 125 | 160 | 20 | 18.5 |
125-160 | 160 | 32 | 30 | |
125-200 | 160 | 50 | 45 | |
125-250 | 160 | 80 | 75 |
CQB-L型磁力泵的故障原因及排除方法
故障現(xiàn)象 | 原 因 分 析 | 排 除 方 法 |
泵不出水 | 1、 水泵反轉(zhuǎn) 2、 進(jìn)水管漏氣 3、 泵腔儲水不足 4、 電壓太高、啟動時(shí)聯(lián)軸器打滑 5、 吸程太高 6、 閥門沒有打開 | 1、 調(diào)整電機(jī)旋轉(zhuǎn)方向 2、 杜絕漏氣 3、 增加儲水量 4、 調(diào)整電壓 5、 降低泵安裝位置 6、 校正或改變閥門 |
流量不足 | 1、 吸入管徑大小或堵塞 2、 葉輪流道阻塞 3、 揚(yáng)程過高 4、 轉(zhuǎn)速不夠 | 1、 調(diào)換或清洗進(jìn)水管 2、 清洗葉輪 3、 開大出水閥 4、 恢復(fù)額定轉(zhuǎn)速 |
揚(yáng)程過低 | 1、 流量過大 2、 轉(zhuǎn)速太低 | 1、 關(guān)小出水閥 2、 恢復(fù)額定轉(zhuǎn)速 |
澡音太大 | 1、 泵軸嚴(yán)重磨損 2、 軸承嚴(yán)重磨損 3、 外磁鋼或內(nèi)磁鋼與隔離套接觸 4、 密封環(huán)與葉輪研磨 5、 冷卻箱內(nèi)滾動軸承磨損 | 1、 更換泵軸 2、 更換軸承 3、 拆除泵頭重新組裝 4、 更換止推環(huán)、密封環(huán) 5、 更換滾動軸承 |
漏液 | 1、 O型密封圈損壞 | 1、 更換O型密封圈 |