日韩午夜在线观看,色偷偷伊人,免费一级毛片不卡不收费,日韩午夜在线视频不卡片

產品|公司|采購|招標

廣電計量檢測集團股份有限公司

3D-tracking 單顆粒三維跟蹤及納米成像模塊

參考價面議
具體成交價以合同協議為準
  • 公司名稱天津東方科捷科技有限公司
  • 品       牌
  • 型       號
  • 所  在  地
  • 廠商性質其他
  • 更新時間2023/3/5 10:50:56
  • 訪問次數232
產品標簽:

在線詢價收藏產品 點擊查看電話
東方科捷科技有限公司 Orient KOJI (Hongkong) Ltd.主營業務包括:代理銷售、研發生產用于科學研究及測試用高技術設備、附件、耗材及服務;公司基于專業的技術及研發團隊,為國內科研團隊和測試領域提供化的設備配置和測試方案;代理銷售品牌:HORIBA Scientific(堀場),ISS(ISS公司),Oxford(牛津),Otsuka(大塚),HITACHI high-technology (日立高新),Hamamatsu Photonics (濱松光子學),UltraFast System,SPECTRA-PHYSICS(光譜物理),Semrock;主要代理產品:l HORIBA Scientific 光譜儀、穩態瞬態熒光光譜儀、激光共焦拉曼成像光譜儀(Raman)、納米拉曼成像光譜儀(nanoRaman)、陰極射線發光光譜儀CL;x射線熒光光譜儀(油中硫分析儀),碳/硫氧/氮/氫元素分析儀;x射線熒光顯微鏡;輝光放電--元素深度分布分析儀(GD-OES),橢圓偏振光譜儀;l ISS公司的激光共焦多維熒光成像系統FLIM/PLIM/FCS,激光共焦超分辨成像顯微鏡STED-ALBA;特色:時間分辨的空間分布成像;時間分辨的空間超分辨成像;壽命范圍100ps-100ms;波長范圍可選350nm-1600nm;二維振鏡掃描標準配置,自動可調針孔共焦;l Oxford公司的低溫恒溫器及磁場系統;l HITACHI公司的二手CDSEM(工業)和FESEM;l 飛秒瞬態吸收光譜儀fs-TAS; 飛秒時間分辨拉曼光譜儀;l 專業光致發光量子效率測試系統—覆蓋紫外可見近紅外波長范圍(350-1600nm),包括上轉換發光,單態氧發光量子效率測試;提供溫度變化環境;Orient KOJI自有產品l QY-2000 積分球熒光光譜儀用于重現性的光致發光量子效率測量;l EzTime-PL 時間分辨調制模塊,用于上轉換壽命和EL時間分辨發光光譜測量;l TAP-02 高溫熒光附件;用于熱穩定性及熱猝滅熒光測試;l Cryo-77液氮低溫恒溫器 (77-500K);l 定制量子效率測試系統;l 定制相關激光共焦掃描、量子效率、光譜(成像)測量、時間分辨(成像)、磁場、低溫等集成技術的測試系統;
3D-tracking 單顆粒三維跟蹤及納米成像模塊
3D-tracking 單顆粒三維跟蹤及納米成像模塊 產品信息

3D Nanoimaging and Single-Molecule Tracking Upgrade

Within the past few years, several methods have been devised in order to obtain images with nanometer resolution of cellular features using an optical microscope (STED, PALM, STORM). Although powerful, these methods are quite inefficient when detecting sparse nanostructures in an image. Also they are inadequate to detect the dynamics of chemical reactions which occur in the sub-second time scale in nanometer-size 3D structures, which are continuously moving and changing shape.

With NanoImaging approach to super-resolution, the laser beam does not scan the sample following a predetermined pattern as is the case in raster images. Instead, the laser scanning imaging is based upon a feedback algorithm where the path followed by the laser beam is continuously adjusted and decided during the scan according to the shape of the object to be imaged. The algorithm moves the laser spot at a fixed distance from the object's surface; as the position of the laser spot and its distance from the surface are known parameters, they are utilized to reconstruct the shape of the object. 3D cellular structures can be resolved down to 20-40 nm with a precision of 2 nm in a matter of a few seconds.

The sequence of operations for using the SMT NanoImaging is straightforward: firstly, a confocal image of the area of interest is acquired; then, the object to be imaged is identified by the user. The SMT NanoImaging is activated through the switch and the laser beam is positioned at a distance of 100-200 nm from the center of the object. As the laser spot approaches the surface to be imaged, the amount of fluorescence increases. Yet, the increase in fluorescence depends upon the distance as well as upon the concentration of the fluorophores and their respective quantum yield. In order to separate the effect of the distance from the effect due to the concentration, the position of the spot is forced to oscillate perpendicularly to the surface. That is, the intensity of the fluorescence changes during the oscillation (Figure 1).

Figure 1. Schematics of the modulation tracking technique. The beam spot travels in a circular orbit around the object and its distance from the object's surface is varied periodically at a set frequency; typically, for each orbit the number of oscillations is between 8 and 32 depending upon the size of the object. These small oscillations of the radius are used to calculate the modulation function of the orbit, from which the distance of the spot from the surface is determined.
The modulation function is defined as the ratio between the alternating part and the average part due to the local fluorescence of the surface. Practically, the modulation is the ratio between the spatial derivative of the PSF and the intensity. The modulation function increases quasi linearly as a function of the distance from the surface and this feature allows for its use in determining the distance of the laser spot from the surface along the orbit. In this way, the transversal shape of the object is calculated and reconstructed.

Tracking Methodology XY-axis using galvo-controlled mirrors
Z-axis using piezo-controlled stage
Maximum Resolution 20 nm ± 2 nm
Data Acquisition Frequency 32 to 256 KHz
Circular Orbit Frequency 2 KHz
Detector Internal PMT of FV1000/FV1200
Detection Electronics ISS Photon Counting Unit
Computer 3 GHz, 4GB RAM, 200 GB hard drive, 27" monitor (minimum specifications shown)
Acquisition and Analysis Software SimFCS by Globals Unlimited

Below is a schematic of the NanoImaging units and its connections to the FV1000 confocal microscope. A switch box allows for the user to operate the FV1000 in the standard mode of operations, or to activate the NanoImaging system. When in nanoimaging operation, the galvo-mirrors of the FV1000 are controlled through the electronics provided by ISS. The signal is collected by the internal detectors of the FV1000 and diverted to the ISS photon counting data acquisition unit. Molecules are tracked in the XY plane using the galvo-controlled mirrors of the FV1000 and in the z-axis by a piezo-controlled stage. Instrument control, data acquisition and display are done on a separate computer.

The right section includes the instrument components (PC, control electronics, scanner and laser launcher). The left section of the schematics includes the components provided by ISS with the upgrade package.

Nanometer-scale Imaging by the Modulation Tracking Method
Lanzano, L., Digman, M.A., Fwu, P., Giral, H., Levi, M., Gratton, E.
J Biophotonics, 2011, 4(6), 415-24.
Measurement of Distance with the Nanoscale Precise Imaging by Rapid Beam Oscillation Method
Lanzano, L., Gratton, E.
Microsc Res Tech, 2012, 75(9), 1253-64.
Real-time Multi-Parameter Spectroscopy and Localization in Three-Dimensional Single-Particle Tracking
Hellriegel, C., Gratton, E.
J R Soc Interface, 2009, 6, Suppl 1:S3-14.
Real-time Nanomicroscopy Via Three-Dimensional Single Particle Tracking
Katayama, Y., Burkacky, O., Meyer, M., Bráuchle, C., Gratton, E., Lamb, D.C.
Chemphyschem, 2009, 10(14), 2458-64.
Distance Measurement by Circular Scanning of the Excitation Beam in the Two-Photon Microscope
Kis-Petikova, K., Gratton, E.
Microsc Res Tech, 2004, 63(1), 34-49.

15168338725
產品對比
QQ

咨詢中心

在線客服QQ交談

市場部QQ交談

發布詢價建議反饋
回到頂部

Copyright hbzhan.comAll Rights Reserved

環保在線 - 環保行業“互聯網+”服務平臺

對比欄

提示

×

*您想獲取產品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息:

主站蜘蛛池模板: 来宾市| 行唐县| 常德市| 凤台县| 新闻| 沛县| 古丈县| 赣州市| 垫江县| 扎赉特旗| 玛多县| 阜新市| 景东| 桂平市| 嘉兴市| 军事| 仪征市| 卢龙县| 焉耆| 星子县| 进贤县| 合川市| 赣榆县| 横峰县| 安陆市| 茌平县| 绥中县| 扎囊县| 会理县| 大新县| 宜丰县| 锦屏县| 巴青县| 三门峡市| 汾西县| 义马市| 双柏县| 密云县| 延津县| 五大连池市| 陈巴尔虎旗|