NT65-200/02φ21803.1D-W1
產品編號 產品名稱 產品大類
ALLWEILER-TYPE:NT65-200/02 #218離心泵
ALLWEILER-NT65-250/258 U3.1D-W1油泵
ALLWEILER-TRF1300R46E18.5V16W203
ALLWEILER-TRF1300 R46U-18.4-V16-W203泵
ALLWEILER-SNF440ER46U3W1-PN16/PN40螺桿泵
ALLWEILER-AFI40 螺桿泵
ALLWEILER-SPF40R46U8.3-W20 潤滑泵
ALLWEILER-NIT32-200-01Φ189 U5A-W4-38/30熱油泵
ALLWEILER-SPF10R46G8.3-W20 減速機油泵
ALLWEILER-SPF/M40R38-W16 ISO上料泵
ALLWEILER-TRL440-46,429L/min螺桿泵
ALLWEILER-LV25/5/125-U2.3D-W1-V 10122/00泵
ALLWEILER-NB 50-200/205 U3.11D W19-28/25泵
ALLWEILER-2/32-200 205 U5A-W4-42/350泵
ALLWEILER-NT54-200/02 φ218 03.1D-W1泵
ALLWEILER-TRILUB440R46-W115
ALLWEILER-TRILUB140R46-W115
ALLWEILER-SNS1300ER42U12.1-W1
ALLWEILER-TRILUB280R46-W115
ALLWEILER-SNS1300ER46U12.1-W1
ALLWEILER-SNF280ER46U12.1-W1
ALLWEILER-SNS1300ER46U12.1-W1
ALLWEILER-SNS660ER44U12.1-W1
ALLWEILER-SNS1300ER42U12.1-W1
ALLWEILER-SNF440ER40U12.1-W1
ALLWEILER-NTT80-250Φ235 U5A-W4
ALLWEILER-TRILUB40R41-W115
ALLWEILER-NTT 200-400 熱油泵
三螺桿泵開機
1 啟動
◆在啟動前,要完荃打開泵吸人側和壓力側的所有開關裝置。
◆內置安全閥的泵,一般安全閥掉啟跳壓力設定為工作壓力+10%,安全閥是按用戶要求設計執行。只要壓力管道中有截止閥或有阻塞的可能性而導致壓力升高,就必須安裝安全閥。
◆啟動時,系統出口側安裝的排氣閥必須打開直到泵吸人側的空氣排完:一有液體從中冒出就可關閉該閥。因泵是自吸式的,無需反壓就可自動排氣。
應檢查貯液罐中的液位,當系統運行時,該液位不能低于限定的蕞小值,否則應添加至所需量。
2 驅動打開電動機。
注意請注意產品相關的驅動特性。請參閱電機制造商的操作說明書。
3檢查運行參數
◆當電機達到其工作轉速時,用真空計和壓力表測量入口壓力和泵出口壓力。
◆電機不應過載。軸功率可用一安培表來檢查。在這種情況下,也要檢查輸送液體的溫度和粘度。其值應和訂單數據表或驗收記錄中的值相比較。
注意若壓力誤差增大,有可能是配裝的安全閥將介質從排出側泄漏到吸入側(循環)。循環導致介質溫升,壓力偏差和溫升可用壓力表和溫度計測得。則應立即找出原因并消除,以避免因過熱和因此的粘度降低而損壞泵。
三螺桿泵的使用壽命長,不易出故障,運行可靠。前蘇聯的標準提出泵輸送清潔的礦物油(運動粘度不小于0.4cSt和溫度達60℃)時,從啟用到大修應不少于25000h,平均工作期的故障出現間隔不少于6000h。當流量下降15%時,認為泵的壽命終了。日本川崎產品平均壽命10萬h以上,IMO公司產品壽命一般為3~20年。我國的產品輸送清潔的潤滑性介質時,壽命也普諞可達數萬小時,甚至更長。
NT65-200/02φ21803.1D-W1