產品型號:JSR0403
產品名稱:減壓蒸餾測定儀(JSR0403)
產品說明:
JSR0403自動減壓蒸餾測定儀
一、符合GB/T9168、ASTM D1160標準
二、主要技術參數:
循環水溫度范圍:0~60℃
殘壓范圍:1mmHg~50mmHg
殘壓波動范圍:≤10Pa(殘壓<1000Pa)
≤1% (殘壓≥1000Pa)
回收體積分辨率:0.1mL
蒸餾溫度分辨率:1℃
液體溫度分辨率:0.1℃
整機功耗:2KW
外形尺寸:900×480×820=長×寬×高(mm)
工作電源:AC220V±10% 50HZ
三、性能及特點:
1、儀器采用單片機控制,液晶屏顯示,實時顯示蒸餾全過程及蒸餾溫度、量筒室溫度、油品液體溫度、加熱功率、殘壓壓力、回收體積、每10%體積下的溫度和對應的常壓溫度、蒸餾速度等參數。
2、自動逐步減壓,自動控制殘壓,保證做樣過程中殘壓的穩定性。
3、自動調節加熱功率,使蒸餾速度達到標準的要求。
4、采用進口溫度傳感器,通過進口溫控儀調校,使檢測到的蒸餾溫度與水銀溫度計一致。
5、采用特制玻璃量筒。玻璃量筒在儀器上校正一次后,就可使用。一臺儀器可使用五支量筒循環做樣。
6、具有強大的計算與存貯功能,根據真空壓力可換算出各體積下實測溫度對應的常壓溫度。儀器內可存貯24個結果,循環覆蓋,結果也可由打印機輸出。
7、提供終餾點結束、回收體積結束、蒸餾溫度結束、手動結束等多束方式。
8、操作簡便、價格便宜,性能超過國外同類儀器。
JSR0403 automatic vacuum distillation tester
I. It conforms to GB/T9168 and ASTM D1160 standards
Ii. Main Technical parameters:
Circulating water temperature range: 0 ~ 60℃
Residual pressure range: 1mmHg ~ 50mmHg
Residual pressure fluctuation range: ≤10Pa (residual pressure <1000Pa)
≤1% (residual pressure ≥1000Pa)
Recovered volume resolution: 0.1ml
Distillation temperature resolution: 1℃
Liquid temperature resolution: 0.1℃
Overall power consumption: 2KW
Dimensions: 900×480×820= Length × width × height (mm)
Power supply: AC220V± 10% 50HZ
Iii. Performance and Characteristics:
1. The instrument adopts single chip microcomputer control and LCD display to display real-time distillation process, distillation temperature, measuring cylinder chamber temperature, oil liquid temperature, heating power, residual pressure pressure, recovery volume, temperature per 10% volume, corresponding atmospheric temperature, distillation speed and other parameters.
2, automatic step decompression, automatic control of residual pressure, to ensure the stability of the residual pressure during the sample making process.
3. Automatically adjust the heating power to make the distillation speed meet the standard requirements.
4. Adopt imported temperature sensor and adjust by imported temperature controller to make the detected distillation temperature consistent with mercury thermometer.
5. Special glass measuring cylinder is adopted. The glass gauge can be used after it has been calibrated once on the instrument. One instrument can use five measuring cylinders to circulate samples.
6. With powerful functions of calculation and storage, the atmospheric temperature corresponding to the measured temperature under each volume can be converted according to the vacuum pressure. 24 results can be stored in the instrument, and the results can also be output by the printer.
7. Provide the end of the final distillation point, the end of the recovery volume, the end of the distillation temperature, manual end and other multi-beam methods.
8. Simple operation, low price and superior performance to similar foreign instruments.